ELECTRONIC CONTROL WITH CONNECTIONS
ELEKTRICAL INSTALLATION
The electronic control unit supplied is required for operation
of the wing gate actuator. This control unit comprises an
electronic microprocessor-control system employing the latest
technology. It may be used for the connection of 1 or 2
motors and offers all connection possibilities and functions
necessary for safe and reliable operation.
The electrical connections for single- or double gates are
given in Illustration 2.
The control box containing the motor control module is to be
fitted with cable entry at bottom. It should not be continuously
exposed to direct sunlight. For weather protection, we
recommend the fitting of a small protection roof.
Thanks to the electronic control unit, fine adjustment of the
push-pull torque is possible. When correctly adjusted, gate
movement can be easily blocked by hand.
For the OPEN and CLOSED positions, the gate requires a
stable end stop as the swing gate actuator unit is not
fitted with limit switches and the electronic controls are
switched off by time.

CONNECTION OVERVIEW

The control unit should be connected up last, i.e. after the
motor has been mounted, the necessary cables laid and the
Infrared Sensors or contact strips fixed in place.
In the case of permanent mounting, means of separating the
system from the mains must be provided. The contact
spacing of the main switch used in this connection must be at
least 3 mm.
NOTE:
In these instructions, relay contacts are designated as
NC (normally closed) and NO (normally open).
• NC contacts are closed, and open when actuated
• NO contacts are open, and close when actuated
709112B-GB - 05.2004
1
2
OVERVIEW
TERMINAL
DESCRIPTION
PE
Earth supply cord
PE
Earth motor 1
PE
Earth motor 2
Capacitor motor1
C1
Direction CLOSED (L1.1) motor 1
1
MP
2
Direction OPEN (L1.2) motor 1
3
Capacitor motor 1
C1
Capacitor motor 2
C2
Direction CLOSED (L1.1) motor 2
4
MP
5
6
Direction OPEN (L1.2) motor 2
C2
Capacitor motor 2
7
Flashing light MP 230Volt ˜
8
Flashing light L1 230Volt ˜
9
E-lock drive NO
10
E-lock drive NO
11A
Safety input OV (socket module 1)
12A
Safety input +24V (socket module 1)
13A
Switching input 1 (socket module 1)
14A
Limit switch contact 1 (factory bridged)
15A
Limit switch contact 1 (factory bridged)
16A
Push button motor 1 only, NO
17A
Push button motor 1 only, NO
11B
Safety input 0V (socket module 2)
Safety input +24V (socket module 2)
12B
Switching input 2 (socket module 2)
13B
Limit switch contact 2 (factory bridged)
14B
Limit switch contact 2 (factory bridged)
15B
Push button motor 1 + 2 NO
16B
Push button motor 1 + 2 NO
17B