6 Installation

Before installing the product, remove the
transparent blue protective film from the
cover.

6.1 Connection of the cables

Once the cover is removed, you can access to a board
with removable connectors and to a switch board
with three RJ45 connectors and a SFP slot.

6.1.1 Connector board description

J26-J27
J8
J7
J9
J6
J22-
J23
J1
Fig. 12
MNVCCOMB_2131_EN
J25
J11
F1
BOARD DESCRIPTION
Connector Function
J1
Main power supply line
F1
Main power supply fuse
J6
Power supply output
24Vac
J7
Power supply output
24Vac
J8
24Vac output, for washer
and command relay
input from the VIDEOTEC
camera
J9
24Vac output, for washer
and command relay
input from the VIDEOTEC
camera
J22
BNC (Video 1) IN
J23
BNC (Video 1) OUT
J26
BNC (Video 2) IN
J24
J27
BNC (Video 2) OUT
F2
24Vac power supply
output fuse
J10
J24
8-pole connector IN (the
contacts of connector
J24 correspond to the
contacts of connector
J25)
J25
8-pole connector OUT
F2
(the contacts of con-
nector J24 correspond
to the contacts of
connector J25)
J10
10-pole connector IN
(the contacts of con-
nector J10 correspond
to the contacts of
connector J11)
J11
10-pole connector
OUT (the contacts of
connector J10 corre-
spond to the contacts of
connector J11)
Tab. 2
Length of conductor stripping: 5mm.
Terminals - Nominal
section of the cables
used
from 0.2mm² (24AWG)
up to 2.5mm² (13AWG)
from 0.2mm² (24AWG)
up to 2.5mm² (13AWG)
from 0.2mm² (24AWG)
up to 2.5mm² (13AWG)
from 0.2mm² (24AWG)
up to 2.5mm² (13AWG)
from 0.2mm² (24AWG)
up to 2.5mm² (13AWG)
from 0.2mm² (24AWG)
up to 1.0mm² (17AWG)
from 0.2mm² (24AWG)
up to 1.0mm² (17AWG)
from 0.2mm² (24AWG)
up to 1.0mm² (17AWG)
from 0.2mm² (24AWG)
up to 1.0mm² (17AWG)
13