Design And Function; Scope Of Delivery - WIKA LH-10 Mode D'emploi

Masquer les pouces Voir aussi pour LH-10:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Specifications / 4. Design and function
Output signals
Signal type
Current (2-wire)
Current (3-wire)
Voltage (3-wire)
Power supply
The power supply depends on the selected output signal.
4 ... 20 mA:
DC 10 ... 30 V
0 ... 20 mA:
DC 10 ... 30 V
DC 0 ... 5 V:
DC 10 ... 30 V
DC 0 ... 10 V:
DC 14 ... 30 V
DC 0.5 ... 2.5 V:
DC 5 ... 30 V (suitable for battery
operation)
For special model numbers, e.g. LH-10000, please note the specifications stated on the delivery note.
For further specifications see WIKA data sheet PE 81.09 and the order documentation.

4. Design and function

4.1 Description
The prevailing pressure is measured at the sensor element through the deformation of a diaphragm. By supplying
power, this deformation of the diaphragm is converted into an electrical signal. The output signal from the pressure
transmitter is amplified and proportional to the prevailing pressure.

4.2 Scope of delivery

Cross-check scope of delivery with delivery note.
WIKA operating instructions submersible pressure transmitter, model LH-10
Signal
4 ... 20 mA
0 ... 20 mA
DC 0 ... 5 V
DC 0 ... 10 V
DC 0.5 ... 2.5 V
Ingress protection (per IEC 60529)
IP 68
Permissible temperature ranges
Fluid
- PUR cable: -10 ... +50 °C
- FEP cable:
-10 ... +85 °C
Ambient:
-10 ... +50 °C
Storage:
-30 ... +80 °C
Submersion depths
Submersible pressure
transmitter with FEP cable:
Submersible pressure
transmitter with PUR cable:
CE conformity
EMC directive 2004/108/EC, EN 61326 emission (group 1,
class B) and immunity (industrial application)
up to 100 m
up to 300 m
9
EN

Publicité

Table des Matières
loading

Table des Matières