3.8 Screwing the cover onto the module housing

▶ Attach the enclosed adhesive label "CM-RC-01" into
the cover of the terminal box.
▶ Then screw the protective earth conductor to the
terminal box cover.
▶ Put the terminal box cover on the compressor mod-
ule housing and fasten it using the 6 enclosed
screws (M5 x 70 mm).

4 Mounting the optional CM-RC-01 extension kits

Required components and procedure to follow for
mounting the optional extension kits of the compressor
module add-on kit:
• Mounting and connecting valve flanges and solenoid
valves for capacity control (CRII) and/or start unload-
ing (SU).
• Mounting and connecting the pressure transmitters.
• Mounting and connecting the liquid injection.
22
• Mounting and connecting the additional fan.
WARNING
The compressor is under pressure!
Serious injuries are possible.
Depressurize the compressor!
Wear safety goggles!
After mounting new components such as discharge gas
temperature sensor, pressure transmitter, injection
nozzle or injection valve:
WARNING
Serious injuries are possible. New component
may suddenly become detached.
Check the thread.
Carefully screw in the new component. Observe
the tightening torques!
Perform a tightness test before commissioning!
After assembly of all components:
NOTICE
!
!
Refrigerant or oil can escape after installation
work on the compressor.
Carry out a leak test before commissioning!
4.1 Mounting the extension kit "Capacity
control" (CRII) and "Start unloading" (SU)
Information
In order to allow the solenoid valves for capacity
control (CRII) and start unloading (SU) to be
mounted, the corresponding CRII and SU cylin-
der heads must already be pre-installed on the
compressor.
For safety references and installation descrip-
tions for the CRII or SU cylinder heads, includ-
ing mounting positions and exact equipment of
the cylinder banks, see Technical Information
KT-101 and KT-110.
▶ Remove the oval flange and seal from the CRII/SU
cylinder head and clean the sealing surface.
▶ Apply a new seal, paying attention to the guide pin
positions!
▶ Use new screws to fasten the solenoid valve. Altern-
ately tighten the screws (tightening torque 80 Nm).
NOTICE
!
!
Risk of compressor damage!
Use only suitable original solenoid coils!