How to proceed:
1.
0.
F, G
Loosen the Allen screws on both sides of the spotlight and tilt the spotlight to allow access to the slot of the installation
bracket.
Fasten the installation bracket to the ground/base.
Align the spotlight and tighten the Allen screws on both sides.
ProfiPlane LED 320/DMX/02
How to proceed:
1.
0.
H, I
Install OASE the ground installation cup.
Place the spotlight into the OASE ground installation cup and fasten with three countersunk head screws.
− When routing the connection cable do not exceed the min. bending radius.
ProfiRing LED 320/DMX/02
1.
How to proceed:
0.
J, K
Undo the screws of the clamping holder.
Insert the Komet nozzle 10-12 or 10-14 through the centre hole so that the nozzle is flush with the surface of the spot-
light or protrudes slightly beyond it.
Tighten the clamping holder screws.
ProfiLux LED Spot 1500/DMX/02, ProfiLux LED Flood 1500/DMX/02
1.
How to proceed:
0.
L, M
Loosen the Allen screws on both sides of the spotlight and tilt the spotlight to allow access to the slot of the installation
bracket.
Fasten the installation bracket to the ground/base.
Align the spotlight and tighten the Allen screws on both sides.

Connecting the spotlights

Note!
• Do not exceed the max. connected load (see type plate)!
• Adhere to the max. cable length per connection in order to limit the voltage drop. An excessive voltage
drop can lead to malfunctions.
• Only use original cables from OASE.
• Close off any unused slots with blind plugs and rubber seals.
1.
How to proceed:
0.
A, N
Remove the protection cap from the unit.
Fit the connector of the connection cable and secure with the two screws (max. 2.0 Nm).
− Ensure that the rubber seal is clean and fits exactly.
− Replace the rubber seal if damaged.
Connect further connection cables in the same way.
Commissioning/start-up
Attention! Strong optical radiation from LEDs of the risk group 2.
Possible consequences: Damage to eyes.
Protective measures:
• Do not look into the spotlight directly or for a long time when it is on.
• Do not direct the spotlight at persons.
For information about controlling the LEDs please read the instructions for use of the "Underwater LED Driver
/DMX/02".
37744_04-14_GA_ProfiLED_110_320_17 17
- GB -
11.04.2014 11:53:46
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Profiplane led 110/dmx/02Profilux led 320/dmx/02Profiring led 320/dmx/02Profiplane led 320/dmx/02Profilux led spot 1500/dmx/02Profilux led flood 1500/dmx/02 ... Afficher tout

Table des Matières