POSSIBLE PROBLEMS / CORRECTIVE ACTION

Possible problems

The burner does not light up
The burner does not burn smoothly or goes out
Unstable blowing flames
Large plume of flame on the burner surface
Flame at the injector
Burning leak around a union
Insufficient heat
GB
Burning leak behind the adjustment knob
WARANTY PERIOD -
Years
2
Heruntergeladen von
manualslib.de
• Poor gas supply
• regulator not operating properly
• Pipe, valve, venturi tube or burner holes obstructed
• Check that gas is present
• Check the pipe connection
• Contact your servicing agent."
• New cylinder may contain air. Allow the appliance to operate and the
fault will clear itself
• Residual water, following the washing of the burner caps
• Contact your servicing agent.
• The venturi is obstructed (possibly cobwebs)
• Contact your servicing agent."
• The cylinder is almost empty
• Change the cylinder and the fault will clear itself
• Contact your servicing agent.
• Shut off the gas supply immediately
• Leaking union: tighten nuts or change pipe
• Contact your servicing agent.
• Injector or venturi tube obstructed
• Contact your servicing agent.
• Defective valve
• Shut down the stove
• Contact your servicing agent.