8. Make the Electrical Connections
NOTE: The product model number is printed on a label on the pump side of the overflowing bath. This
label also identifies the electrical rating of the product.
WARNING: Risk of electrical shock. Make sure the power has been disconnected before performing
the following procedures. Refer to the "Important Information" section.
CAUTION: Risk of electrical shock. All services must have a Class A Ground-Fault Circuit-Interrupter
(GFCI) which will provide additional protection against line-to-ground shock hazard. A dedicated
service is required for the overflowing bath.
The overflowing bath control and system have been prewired at the factory using 220V hardwire. A
licensed electrician should make a routine service connection to the junction box located on the control
box.
Connect service to the junction box. The junction box contains black and green wires. The grounding
conductor must not be connected to any current-carrying conductor.
A 240 V, 15 A dedicated circuit is required. Provide a Class A Ground-Fault Circuit-Interrupter (GFCI).
Follow local electrical codes.