9. Problem-solving by the installation engineer

Baking out of the heating rods
Moisture can accumulate in the heating rods in especially humid ambient con-
ditions or during long periods of non-use. This is a physical process and not
a manufacturer error. Under certain circumstances, accumulation of moisture in
the heating rods can lead to the FI circuit breaker being triggered.
In this case, it is necessary to bake out the sauna heater under the supervision
of an electrician. To do this, the protective function of the FI circuit breaker must
be switched off. The baking out procedure takes approximately 10 minutes.
The safety function of the FI circuit breaker must subsequently be reactivated.
If the problem persists, consult your supplier.