TRI-LITE HVLS SERIES FANS

RECOMMENDED MAINTENANCE SCHEDULE

!
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. No maintenance shall be done on the fan, mount or guy wires while it is in operation or powered.
2. No maintenance shall be done on the fan controller while powered unless the task involves reprogramming or troubleshooting the
electrical system.
3. No maintenance shall be done within a 20' horizontal radius of the fan and 4' below and none above the blade level while it is in
operation.
4. While doing maintenance on the fan, mount, or guy wires, a safety barrier shall be erected at a radius of 20' of the centre of the fan.
5. The fan controller must be locked out while maintenance is ongoing on the fan, mount, or guy wires.
6. All personnel working on the fan, mount, or guy wires, shall wear the appropriate personal safety equipment as mandated by local,
provincial, and national regulations.
7. A risk assessment shall be performed before any maintenance is done on the fan, mount, guy wires and fan controller.
8. A tailboard meeting shall be performed before any work is done. A checklist shall be completed and shall include any emergency
contacts for the area.

POWER UNIT

Motor
Our motor or gear motor manufacturers supply Canarm with gear motors built for our application.
Designed for use with variable frequency drives.
Maintenance Schedule
Initial Six Months
• Check for hot spots
• Re-tighten all loose electrical connections
Repeat every eighteen months thereafter
Gear Motor
Maintenance Schedule
Initial Eighteen Months
• Check oil level
Every three years thereafter
• Replace oil with recommended equivalent as specified on gear motor (acceptable fill level is within 10mm - 12mm
or closer to the fill level plug).
Blades
The airfoil blades are designed for maximum efficiency and quietness with a minimum air disruption directly below the fan. All our blade
shapes are extruded from aluminum alloy and heat-treated to T-6 condition. They are anodized to .0004 10 Microns clear for corrosion
resistance and ease of cleaning. The blades have a one year warranty.
Maintenance Schedule
Initial Six Months
• Ensure blades are intact, level and clean as required
Every eighteen to thirty-six months thereafter
Drop/Mounting
The drop and mounting system is designed to prevent vibration or horizontal movement from being transferred back into the building
structure. The system is easily installed in almost any building and allows fans to hang level from beams.
Maintenance Schedule
Initial Six Months
• Physical check of fan guy wires, re-tightening of clamps if required
• Check all nuts/bolts/clamps (missing/loose/damaged)
• Physical check of safety cable, re-tightening of clamps if required
Repeat every eighteen months thereafter