TRI-LITE HVLS SERIES FANS
INSTALLING THE EXTENSION
1. Using a 7/8" wrench, fasten top plate of extension to the bottom
plate of the standard mount using M14 bolts, nuts and washers.
2. Position the safety cable as per Figure 5, loop at both ends.
3. Using a 7/16" wrench, fasten the cable clamps 2 per end and as
per typical cable clamp installation (Figure 3). Cable should be
relatively snug.
NOTE:  Every connection between components (mounts,
extensions and fan frame) must include a safety cable as
shown throughout this manual, loop at both ends.
MAIN HUB AND DRIVE ASSEMBLY
(Figure 6)
The package includes:
(1) Hub
(1) Fan Frame
(1) Safety Washer &  Bolt
(1) Gear Motor
(3) Safety Clips
(4) Bolts M14-2.0 x 40mm
(8) Washers Flat M14
(4) Nylock M14-2.0
(1) Cable 5mm SS  (Length 3.4')
(4) Cable Clamps 5mm
INSTALLING THE MAIN HUB
& DRIVE ASSEMBLY
1. Using a 7/8" wrench, fasten the top plate of fan frame to the
bottom plate of the standard mount using M14 bolts, nuts and
washers.
2. Position the safety cable as per Figure 7, loop at both ends.
3. Using a 7/16" wrench, install and fasten cable clamps 2 per end
as per Figure 3. Cable should be relatively snug.
TRI-LITE HVLS-M (04_29_15)
FIGURE 5
Typical 1m
Safety Cable
FIGURE 6
FIGURE 7