TRI-LITE HVLS SERIES FANS
INSTALLING GUY WIRES
1. Determine mounting position on ceiling and establish the
angle between 45˚ - 60˚ for the cable. Determine correct
location on the I Beam to drill 5/16" diameter hole for the eye
bolt. For example, if fan is 3.3' down from ceiling, cables
should be mounted approximately 3.3' away from fan.
2. Using a 3/8" wrench, install eye bolt with nuts and washers in
I Beam as per Figure 9.
3. Measure the run of cable required and cut cable approximately
2' longer. NOTE: longer runs than 14' will require
additional cable.
4. Secure it with 1 thimble and 2 cable clamps (Figure10).
Repeat using the other 3 pieces of guy wire cables, thimbles
and cable clamps (Figure10).
5. Guy wires should be taut but not over-stressed to allow free
self-levelling. They should also be to approx. 90˚ apart
(Figure 11).
IMPORTANT LEVELLING INSTRUCTIONS:
Check to see if the fan is level by placing your level vertically
on the side of the fan frame. If adjustment is needed, slightly
tighten the guy wires on the appropriate side.

BLADE ASSEMBLY

WARNING! TO REDUCE THE RISK OF INJURY TO
!
PERSONS, OBSERVE THE FOLLOWING:
• Do not bend the blade brackets when installing the brackets,
balancing the blades, or cleaning the fan.
• Do not insert foreign objects in between rotating fan blades.
The assembly includes:
(3) Blade Plates
(9) Bolts M10-1.5 x 60mm
(9) Washers Flat M10
(3) Blades
INSTALLING THE BLADE ASSEMBLY
1. Using a 5/8" wrench, clamp a blade between blade plate and
hub using M10 bolts and washers. There are 3 bolts per blade.
2. Continue until all 3 blades have been fastened and tighten down.
3. Turn the fan by hand to ensure that there are no obstructions with
the blades.
HUB COVER
The assembly includes:
(1) Hub Cover
(3) Stando M/F M10
(3) Bolts M10-1.5x12mm
(3) Washers Flat M10
(3) Washers Lock M10
1. Line up the holes in the stando attached to the fan frame with the
holes in the bottom of the hub cover.
2. Using M10 bolts with a lock washer and a flat washer, thread each
M10 bolt into each of the holes in the hub cover and standoffs.
3. Tighten bolts with a 5/8" wrench and make sure hub cover is secure.
TRI-LITE HVLS-M (04_29_15)
NOTE:
Fans hanging lower than 10' will require additional cable.
FIGURE 11
o
90
FIGURE 12
FIGURE 13
Standoff
Hub Plate
Washers Flat M10
Washers Lock M10
Bolts M10-1.5x12mm
Page 7 of 13