Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
english | 16
3 Never touch both terminals at the same
time when the charger is in operation.
3 Always disconnect the power cord from the
socket before connecting the charging cable
to the battery or disconnecting it from the
battery.
3 On completion of charging and trickle charging
for a battery permanently connected in the
vehicle, always start by disconnecting the
terminal (–) (black) of the charger from the
(–) terminal of the battery.
3 In the event of malfunctions and damage,
always disconnect the charger from the mains
current immediately.
3 The charger is only to be repaired by qualified
specialists.
3 Disconnect the charger from the mains current
and the battery when not in use.

Product description

This unit is designed for charging open as well as
a wide range of closed lead acid batteries used
for passenger cars, motorcycles and certain other
vehicles – e. g. WET batteries (with liquid electro-
lyte), GEL batteries (with electrolyte in gel form)
or EFB (Enhanced Flooded Battery) batteries.
The battery capacity ranges from 12 V (5 Ah) to
12 V (120 Ah).
Automotive Aftermarket
C1-Komplett-040914.indd 16
The special device concept permits re-charging up
to virtually 100 % of the battery capacity.
The charger features a total of 1 charging mode
for different batteries in various states. This makes
charging more efficient and reliable.
In contrast to conventional products, the charger
has a special function (pulse charging) which per-
mits the re-charging of more or less flat batteries.
Trickle charging: The charger can be left perma-
nently connected to maintain the full battery charge.
After charging, the charger switches automatically
to the trickle charge mode.
Stringent precautions to prevent incorrect usage
and short circuits guarantee safe working. Thanks
to an integrated circuit, several seconds elapse after
selecting the charging mode before the charger
starts the charging process. This means that the
sparks frequently encountered during the connec-
tion process can be avoided.
In addition, the battery charger is controlled by an
internal MCU (micro-computer unit).
Battery charger | C1 | 04.2015
08.05.15 10:08