8 Care and maintenance

CAUTION
Disconnect the mains plug from the power outlet.
8.1 Care of the power tool
DANGER
Under extreme conditions, when used for working on
en
metal, conductive dust may accumulate inside the tool.
This may have an adverse effect on the tool's protective
insulation. Under such conditions, the tool should be
plugged into a ground fault circuit interrupter (RCD)
and use of a stationary dust removal system and
frequent cleaning of the tool's cooling air slots is
recommended.
The outer casing of the power tool is made from impact-
resistant plastic. Sections of the grip are made from a
synthetic rubber material.
Never operate the power tool when the air vents are
blocked. Regularly clean the power tool's air vents care-
fully with a dry brush. Do not permit foreign objects to
enter the interior of the tool. The motor's fan will draw
dust into the casing and an excessive accumulation of
conductive dust (e.g. metal, carbon fiber) may cause
electrical hazards. Clean the outside of the power tool at
regular intervals with a slightly damp cloth. Do not use
a spray, steam pressure cleaning equipment or running
water for cleaning. This may negatively affect the elec-
trical safety of the tool. Always keep the grip surfaces

9 Troubleshooting

Fault
The power tool doesn't start.
The power tool doesn't achieve
full power.
28
of the tool free from oil and grease. Do not use cleaning
agents which contain silicone.
NOTE
Frequent work on conductive materials (e.g. metal, car-
bon fiber) may make shorter maintenance intervals ne-
cessary. Take your individual work place risk assessment
into account.
8.2 Maintenance
WARNING
Do not operate the power tool if parts are damaged,
if the electronic control unit is defective or when the
controls do not function faultlessly. Have the power
tool repaired by Hilti Service.
WARNING
Repairs to the electrical section of the power tool may
be carried out only by trained electrical specialists.
Check all external parts of the power tool for damage
at regular intervals and check that all controls operate
faultlessly.
8.3 Checking the power tool after care and
After carrying out care and maintenance work on the
power tool, check that all protective and safety devices
are fitted and that they function faultlessly.
Possible cause
Interruption in the electric supply.
The supply cord or plug is defective.
The carbon brushes are worn.
The electronic restart interlock is ac-
tivated after an interruption in the
electric supply.
The extension cord's conductor cross
section is inadequate.
Malfunction in the ATC system.
maintenance
Remedy
Plug in another electric appliance and
check whether it works.
Have it checked by a trained electrical
specialist and replaced if necessary.
Have it checked by a trained electrical
specialist and replaced if necessary.
Switch the power tool off and on
again.
Use an extension cord with an ad-
equate conductor cross section.
If necessary, the power tool should be
repaired by Hilti Service.