Internal Blower Preparation - Zephyr Trapeze CTP-E36CSX Guide D'utilisation, D'entretien Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ZEPHYRONLINE.COM

Internal Blower Preparation

1.
Remove internal blower flange
from motor housing by (6) screws.
4. Secure ground wire to underside
of internal blower flange by (1)
3/16*3/8 screw and (1) washer.
7.
Secure motor housing to hood
body by (12) M4*6 screws.
Trapeze Use, Care, and Installation Guide
Installation Instructions
2. Secure internal blower to internal
blower flange by (4) M4*16 screws
from internal blower hardware.
5. Connect 9 pin molex connector
from capacitor cable to 9 pin
molex connector from internal
blower.
8. Connect 6 pin molex connector
from capacitor cable to 6 pin
molex connector from control
box. Connect 2 pin plug from AC
power cable to 2 pin plug from
control box. Secure cables to
hood interior with zip ties and zip
tie holders.
3. Secure AC power wiring box to
internal blower flange by (2) M4*8
screws.
6. Re-install internal blower flange
to motor housing by (6) screws
previously removed from step 1.
9.
Secure capacitor box to internal
hood body by (2) M4*8 screws
and secure ground wire by (1)
3/16*3/8 screws.
13

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Trapeze ctp-e48csxTrapeze ctp-e54csxTrapeze ctp-e60csx

Table des Matières