Operating instructions /
Description of function
The control unit allows a variety of operating modes:
Dead man OPEN / dead man CLOSE
Pressing button
and keeping it pressed causes the
door to open until the OPEN end-of-travel position is
reached. Releasing the button causes the door to
stop. The door is closed by dead man's control, i.e.
pressing button
and keeping it pressed, until the
door reaches its CLOSE end-of-travel position. If the
button
is released during closing, the door stops
instantly.
Dead-man operation with key switch only
for access by persons not specifically
instructed.
Impulse OPEN / dead man CLOSE
By briefly pressing the button
impulse from an external impulse generator, the door
starts to open until reaching the OPEN end-of-travel
position or the door can be stopped beforehand by
pressing button . If button
is pressed again, the
door continues to open. The door is closed by dead
man's control, i.e. pressing button
pressed, until the door reaches its CLOSE end-of-
travel position. If the button
closing, the door stops instantly.
Dead-man operation with key switch only
for access by persons not specifically
instructed.
Impulse OPEN / impulse CLOSE
By briefly pressing button
or generating an impulse
from an external impulse generator the door starts to
open until reaching the OPEN end-of-travel position,
or the door can be stopped beforehand by pressing
button . By briefly pressing button
closing until reaching the CLOSE end-of-travel
position.
This operating mode demands that a safety edge
(menu 35) be installed. If the safety edge is triggered
during closing, the door stops and changes direction.
If the safety edge is triggered during opening, this
has no effect. In the case of a defect, the door can be
closed by pressing button .
First impulse:
The operator starts up and causes the door to travel
to the set OPEN or CLOSE travel limits.
Impulse generated during travel:
Door stops.
A new impulse is generated:
Door continues to travel but in the opposite direction.
Fall-back option in the dead man's mode
Should a safety device, such as the closing edge
safety device, the light grid or the light barrier, be
defective, the CLOSE impulse will be deactivated.
The gate can then be closed in the dead man's mode
only. As soon as the faults affecting the sensors have
been rectified, closing in the pulse mode will be
possible again.

• Status display

Display
_______________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
or
AR-mode / automatic closing
By briefly pressing button
from an external impulse generator, the door starts
opening until reaching the OPEN end-of-travel
position. Or the door was stopped prematurely using
button . After the lapse of the set hold-open time, a
set advance warning time starts running, after which
t h e
g a t e
If button
closing motion of the gate, the AR function
( a u t o m a t i c c l o s e f u n c t i o n ) i s a b o r t e d .
After 20 reversals during the closing motion of the
gate, the AR function is aborted in open position. The
n e x t s t a r t c o m m a n d r e - e n a b l e s i t .
AR-mode with shortened response time via
photocell
Function as described above, but an interruption of
the photocell causes the set hold-open time to be
terminated and the early warning phase to begin.
After the early warning phase has expired, the door
or generating an
automatically closes.
OPEN-CLOSE operation
However, the receiver remains plugged into the drive
in the same operating mode like the one-way control
with the red-green traffic light (optional traffic light
and keeping it
control A800).
Operating sequence for external impulse
is released during
generators:
Generating an impulse in the close position:
Drive starts and moves the door into the open
position
Generating an impulse during the opening:
Door continues to move without being affected
Generating an impulse in the open position:
Door closes
Generating an impulse during the closing:
the door starts
Door stops and opens again
Half-opening of the door
Pressing the ½ button initiates the set half-opening
of the door (menu 32). This function is not available
in dead man's open / dead man's close mode and
also not when a light array is installed.
Lighting and / or early warning light
The control unit has two relay outputs allowing the
switching of lighting or the early warning light (menu
45 and 46).
External command units / impulse generators
The door can be opened and closed via external
command units/impulse generators.
Safety
Connected light barriers and closing edge guards
help avoid accident. The control will only switch to
dead man's c lose mode when it detects a defect.
Key switch function (optional)
The control unit has an input for a key switch. This
allows you to activate the following functions
(menu 50):
Status
Upper end position "Open" reached
Gate end position not reached
Lower end position "Closed" reached
Graphic representation of the gate opening (process sequence)
Graphic representation of the gate closing (process sequence)
Flashing of the inner segments of the segment display: The timer for function „Automatic closing" is active.
or generating an impulse
c l o s e s
a u t o m a t i c a l l y .
is pressed in open position or during the
0
Input J7 for pulse transducer with Open-
Close switching sequence
1
Control panel on the control unit is
blocked.
2
All external control elements are
blocked.
3
Control panel on the control unit and all
external control elements are blocked.
4
For 10 secs. the control panel on the
control unit and all the external control
elements are active.
5
Switching of operating mode to impulse
OPEN / dead man CLOSE.
6
Switch to half opening of the door.
7
Input J7 for pulse transducer with Open-
Stop-Close
8
Input J7 for pulse transducer with Half
Open-Close
9
AR-mode / automatic closing
10
RWA (smoke-heat exhaust) function
The RWA position is actuated
compulsorily when this function is
triggered. To restart the control, a
network reset must be performed.
11
like 10, but inverted entry
12
mutual gate locking
Radio hand transmitter (optional)
Button: Start
½ button for half-opening:
Pulse, AR and open-close modes can be set for both
keys (menu 68).
Function as with the START button, but the door
travels to the set half-open position only.
Button: Light
The light function involves a continuous light that can
be switched on/off independent of the door action.

Maintenance / Checks

For your own safety, we recommend
that prior to initial operation and
whenever required - however at least
once a year, you have the door system
tested by a specialist company.
Service display
If the control unit establishes the need for testing /
inspection, "service" shows up in the display.
Contact a specialist company.
!
Warning
The warning lamp lights when the safety circuit is
open, see troubleshooting guide.