Programming Overview
3-9
Menu-
No.
Selection
Entry
point
Key switch function (J7)
5
0*
Open/Close pulse input
1
Block control panel
2
Block external control elements
3
Block control panel and external control elements
50
4
Activating the control elements for 10 secs.
5
Switch to dead man's Close
6
Switch to half opening of the door
7
Pulse input for Open-Stop-Close
Pulse input for Half Open-Stop-Close
8
9
AR - automatic closing
10
Pulse input for (smoke-heat exhaust) (menu 55)
11
Pulse input for smoke/heat exhaust, inverted (menu 55)
12
Mutual interlocking
Function of external impulse generators (J1)
0*
off
1
Dead man OPEN / Dead man CLOSE
2
Impulse OPEN / Dead man CLOSE
51
Impulse OPEN / Impulse CLOSE
3
Impuls 1/2 Öffnung / Impuls Zu
4
AR - automatic closing
5
6
AR - automatic closing, half opening
7
Open-close operation
8
Open / Close pulse stop as make contact
52
001-256
Entering the control address
Module
0*
off
53
DC-module
1 - 4
Wireless closing edge, RadioSafe
5
6, 7
Reverse
Door setting for smoke-heat exhaust position
55
- -
Exit menu
Programming the START button on the transmitter
60
6
Programming button for 1/2-opening on the transmitter
61
62
Programming the light button on the transmitter
Deleting radio codes
63
Start button operating mode
off
0*
1
Impulse open-stop-close
64
AR - automatic closing
2
Open-close operation
3
- -
Exit menu
Menu
30-
37
(press for 5 sec.)
Item
1x
Menu-
No.
Selection
Entry
point
Open speed (1% - 100% motor speed)
70
0 - 99
7
0 - 99
Close speed (1% - 100% motor speed)
71
Soft run
72
0 - 99
Acceleration time open
73
0 - 39
Braking time open
74
0 - 39
Acceleration time close
75
0 - 39
Braking time close
76
0 - 39
Soft run distance (number of motor revolutions)
0 - 9
Close only before end position (0 - 9 motor revolutions)
77
10 - 19
Open and close before end position (0 - 9 motor revolutions)
Only before open end position (0 - 9 motor revolutions)
20 - 29
Motor brake
78
0 - 9
Type A,
dropout delay
10 - 19
Type B,
Drive select, see separate sheet
79
0*
No drive motor selected
Exit menu
- -
Selecting the door's service intervals
9
0*
no service interval
1
10000 cycles
2
20000 cycles
3
30000 cycles
4
40000 cycles
90
5
50000 cycles
6
60000 cycles
7
80000 cycles
8
100000 cycles
9
120000 cycles
10
150000 cycles
11
200000 cycles
12
250000 cycles
91
Issue of cycles counter
96
Issue of operating hours counter
97
Issue of error memory
98
Issue of software version
Resetting of factory setting
99
- -
Exit menu
Enter
(1% - 100%
motor speed)
(0.1 secs. - 4.0 secs.)
(0.1 secs. - 4.0 secs.)
(0.1 secs. - 4.0 secs.)
(0.1 secs. - 4.0 secs.)
(0 - 350ms)
dropout delay
(0 - 350ms)
-
-
cycles
-
hours
-
-
hours error code
-
-
serial-no. date
(press for 5 sec.)
* Factory defaults