Dometic CFX Serie Notice D'utilisation page 17

Masquer les pouces Voir aussi pour CFX Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
CFX100
4. Connect the black cable to the negative (–) battery terminal (fig. 6, page 5).
Extended DC hard-wiring
A
NOTICE! Damage hazard
To avoid drops in voltage and therefore performance, keep the cable as
short as possible and only disconnect it when necessary.
For this reason avoid additional switches, plugs or power strips.
➤ Determine the required cross section of extended wiring in relation to the total
length from cooling box to battery supply according to fig. 7, page 6.
Co-ordinate axis
l
A
NOTICE! Damage hazard
• For protection of the device the DC cable supplied is fitted with a
fuse. Do not remove the fuse.
Only use the DC cable supplied from the cooling box to in-vehicle
connection point.
• Make sure that the polarity is correct.
To extend the DC hard-wiring, proceed as follows:
1. Before starting up the device for the first time, check whether the operating
voltage and the battery voltage correspond (see type plate).
2. Run the extended wiring from DC cable in-vehicle connection point
(fig. 8 4, page 6) to the battery (fig. 8 6, page 6).
3. Make sure that the cable to the positive (+) battery terminal is protected with an
additional 15 A fuse (fig. 8 5, page 6) close to the battery. Do not remove the
fuse of the supplied DC cable.
4. Connect the supplied DC connection cable (fig. 8 2, page 6) to the in-vehicle
connection point (fig. 8 4, page 6).
5. Plug the DC connection cable (fig. 8 2, page 6) into the DC voltage socket of
the cooling box (fig. 8 1, page 6).
EN
Meaning
Cable length
Cable cross section
Operation
Unit
m
mm²
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cfx 100 professional

Table des Matières