J.
The unit is now ready for connection to the ductwork. The return air duct can be configured as either a rear inlet
or bottom inlet.
Electrical Connections Indoor and Outdoor Units
14AWG stranded copper wire only.
Maintain 10 feet of distance from TV, radio or any communication wiring.
NOTE: See the Wired Controller Operation and Installation Manual for more information.
Step 4 - Leak Testing, Evacuation and Wifi
Refer to the outdoor section Installation Manual for the recommended procedure.
Wifi Pairing
1. Download the "GE SmartHQ" app from Google Play (Android) or the Apple app store (IOS).
After downloading the App:
2. Open the app.
3. Select "Sign In".
4. Sign into your account or register as a new user.
5. Select the "+" icon to add a new device and follow the directions in the app.
31-5000493 Rev. 1
Step 2 - Mounting the Unit (Cont.)
Rear side air inlet
Return Duct
Bottom side air inlet
Return Duct
Step 3 - Electrical Connections
Indoor Unit Terminal Block
Indoor uni t
3wire 14AWG
Control Wiring
Diffuser
Diffuser
Outdoor Unit Terminal Block
Outdoor unit
Power
Wiring