Troubleshooting

If there is a problem, refer to this Troubleshooting Guide.
The Camera Flash does not fire.
• The camera flash is not attached securely to the
camera.
• →Attach the camera's mounting foot securely to the
camera.
• The electrical contacts of the Camera Flash and camera
are dirty.
• →Clean the contacts.
• <
> or <
camera.
• →Wait until the flash is fully recycled and the flash
ready indicator lights up.
• →If the flash ready indicator lights up, but <
<
> is not displayed in the view finder, check whether
this flash unit is securely attached to the camera
hotshoe.
• →If the flash ready indicator does not light up after a
long wait, check whether the battery power is enough. If
the battery power is low, <
the LCD panel. Please replace the battery immediately.
The power turns off by itself.
• After 90 seconds of idle operation, auto power off took
effect if the flash is set as master.
• →Press the shutter button halfway or press any flash
button to wake up.
• After 60 minutes (or 30 minutes) of idle operation, the
flash unit will enter sleep mode if it is set as slave.
• →Press any flash button to wake up.
Auto zoom does not work
• The camera flash is not attached securely to the
camera.
• →Attach the camera flash's mounting foot to the
camera.
The flash exposure is underexposed or overexposed.
• There was a highly reflective object (e.g. glass window)
in the picture.
• →Use FE lock (FEL).
• You used high-speed sync.
• →With high-speed sync, the effective flash range will
be shorter. Make sure the subject is within the effective
flash range displayed.
• You used Manual Flash mode.
• →Set the flash mode to I-TTL or modify the flash output.
Photos have dark corners or only parts of the target
subject are illuminated.
• The focal length of lens exceeds the flash coverage.