Description Of Protective Devices; Thermal Protection - Cebora SPOT 2500 Manuel D'instruction

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

live parts of the power circuit by a tool (diameter
2.5 mm ).
S
Suitable for use in high-risk environments.
NOTES:
Suitable for use in environments with a pollution
rating of 3 (see IEC 60664-1)
2.3

DESCRIPTION OF PROTECTIVE DEVICES

2.3.1 Thermal protection

This machine is protected by a thermostat, which prevents
the machine from operating if the allowable temperatures are
exceeded. In this condition the display will show the error
code E1.
3 INSTALLATION
Only skilled personnel should install the machine. All con-
nections must be carried out according to current regula-
tions, and in full observance of safety laws (regulation CEI
26-10 - CENELEC HD 427).
1. Place the welding machine in a stable and safe position.
Air must circulate freely, both incoming and outgoing,
and the welding machine must be protected from entry
by liquids, dirt, metal filings, etc.
2. Make sure that the supply voltage matches the voltage
indicated on the specifications plate of the welding
machine. When mounting a plug, make sure it has an
Q
O
B
A
P
S
T
R
U
adequate capacity, and that the yellow/green conductor
of the power supply cable is connected to the earth pin.
The capacity of the overload cutout switch or fuses
installed in series with the power supply must be equiv-
alent to the absorbed current I1 of the machine.
Any extension cords must be sized appropriately for the
absorbed current I1.
If the power supply is 115V, the machine may run for
voltages between 96V and 140V.
If the power supply is 230V, the machine may run for
voltages between 190V and 260V.
The machine must be switched off when changing the
power supply.
3. Pacemaker wearers are prohibited from using the
machine or approach the cables.
4. Fully insert the earth cable plug into the + socket and
turn clockwise.
5. Fully insert the gun plug into the - socket and turn clock-
wise.
6. Insert the 3-pin control connector into the socket pro-
vided; if the manual cycle "MAN" is selected, the spot-
welding cycle begins when the torch trigger is pressed.
7. Turn on the welding machine using the switch X on the
back of the machine.
8. To limit exposure to the magnetic field, keep the gun
cable on the side of the hand holding it, avoiding wrap-
ping the cable around.
D
C
E
F
G
H
I
L
M
N
W
V
Fig. 1
Y
X
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2148

Table des Matières