4
Technical specifications
Type CDVI5.0−...
Dimensions
Number of valve locations
Control voltage
Rated value (protected against
incorrect polarity)
Tolerance
Total permitted current
Protection class for completely
fitted CDVI (CDVI with fitted plugs
or covers)
Temperature ranges/storage dur
ation
Ambient/medium temperature
Storage temperature
Recommended storage dur
ation
Materials
Electromagnetic compatibility
Interference emitted
Immunity to interference
1)
Type 4 (hosedown test, test no. 5.7)
2) The CDVI valve terminal is intended for industrial usage.
3) The maximum permitted signal cable length is 10 m.
14
See Pneumatics manual
4, 6, 8, 10, 12
24 V DC
± 10 % (21.6...26.4 V DC)
2880 mA
IP65, IP66, IP67 as per EN 60529
1)
Typ 4
− 5 ... + 50 °C
− 20 ... + 40
Max. 18 months
See Pneumatics manual
Tested as per EN 61000−6−4 (in
dustry)
3)
Tested as per EN 61000−6−2 (in
dustry)
as per NEMA250
°
C
2)
Festo CDVI... 0404b English