Installation Considerations
Not suitable for outdoor use (2-1).
Never install the detector where
the PIR is in constant alarm (LED
on). The LED is off when properly
installed.
Point away from direct and indirect
sunlight (2-2).
Point away from glass or other
objects that rapidly change
temperatures (2-3, 2-4, and 2-5).
5
Terminal Block Wiring
Terminal block (4-15) wiring:
- 9 VDC to 15 VDC (5-1)
- NC alarm contacts (5-2)
- NC tamper contacts (5-3)
- Digital alarm output (5-4)
6
LED Operation
1. Select LED (6-1) operation:
- Jumper position for LED on (6-2)
- Jumper position for LED off (6-3)
2. Non-pet installations only: Create a look-down zone directly below the
detector by removing the tape covering the lens
(6-4).
Note: You cannot cover the look-down zone once the tape is
removed.
3. Replace the cover.
4. To lock the cover (optional):
a. Press the top of the cover tab (6-5) with your fi nger to lift the lower
edge.
b. Lift the lower end of cover tab with your fi nger (6-6) to open it.
c. Insert a fl at head screwdriver in the slot (6-7) in the cover tab opening
and turn it 180° to lock cover. Indicator points down (6-8).
7
Walk Test
Note: Ensure the LED jumper is set to on (6-2).
1. Wait at least 2 minutes after power up to start the Walk Test.
The LED lights for 1 to 2 minutes until the detector
stabilizes and no movement is detected for 2 seconds.
The LED does not light when there is no motion.
2. Watch the LED as you walk to the farthest edge of the pattern. Walk
closer to the detector by crossing the pattern. The LED lights at the
outside edge of the coverage range.
1
Specifi cations
Input Power 1 : 9 VDC to 15 VDC
Current
10 mA @ 12 VDC standby
Draw 1 :
Alarm current 18 mA
Standby
No internal standby battery. For UL Listed Product
Power 1 :
Installations, 4 hours (40 mAh) standby power must be provided by the control unit or by a UL Listed
burglary power supply.
Solid State
Supervised Form "A" normally-closed (NC) rated for 125 mA at 28 VDC, 3 W.
Relay 2:
Tamper 2 :
NC (with cover on) contacts rated at 28 VDC, 125 mA maximum. Connect tamper circuit to a 24-hour
protection circuit.
Digital Alarm
5 V normally, grounded during alarm
Output:
Temperature: -20°F to +120°F (-29°C to +49°C)
For UL Listed installations, the temperature range is +32°F to +120°F (0°C to +49°C)
Humidity:
0 to 95% non-condensing
Dimensions:
4.2 in. x 2.4 in. x 1.9 in. (10.7 cm x 6.1 cm x 4.8 cm)
Pet Immunity: Bosch Security Systems Pet Friendly Blue Line P1-P Passive Infrared (PIR) Detector does not
detect pets up to 30 lb (13 kg) total or numerous rodents. The pet immunity feature was not tested
by UL.
Options:
B335 Low Profi le Swivel Mount Bracket, B328 Gimbal Mount Bracket, and B338 Ceiling Bracket.
These brackets can reduce the detector's range and increase the dead zone area.
Note: You cannot use a camera with the B338 Ceiling Mount Bracket.
1 Use only a Listed limited-power source.
3
Coverage Patterns
Top view (3-1)
Side view (3-2)
Optional look- down (3-3)
4
Mounting
1. Insert a fl at head screwdriver in slot (4-1) and lift to open cover.
2. Select a mounting location. Mount the sensor where an intruder is most
likely to cross the coverage pattern (4-2).
3. Mount the detector 7.5 ft to 9 ft (2.25 m to 2.7 m) above the fl oor (4-3).
4. Pet mounting recommendations:
- Range of pet immunity (4-4).
- Do not point the detector where pets can climb (4-5).
5. Optional: Mount the detector temporarily by peeling the blue tape off the
back of the base to expose the adhesive. Do not use where adhesive
can damage the wall.
6. Mount the base using one of these options:
- for surface or corner mounting, use the appropriate mounting holes (4-
6) and the two fl at head screws and anchors provided.
- use the optional B335 Bracket here (4-7).
- use the optional B328 Bracket here (4-8).
- use the optional B338 Bracket here (4-9).
Note: Do not over tighten the mounting screws. The cover might not attach
correctly.
7. For the wall tamper function, insert the two pan head screws through the
wall tamper knockouts (4-10). If needed, use the anchors provided to
secure the screws.
8. Wire the detector base. Thread the wires through the appropriate
diameter wire knockouts on the detector base (4-11) or on the removable
top insert (4-12).
9. When wiring from below, thread wiring through these wire knockouts that
are perpendicular to the base (4-13).
10. Use the cable ties (4-14) for strain relief.
Bosch Security Systems
130 Perinton Parkway
Fairport, NY 14450-9199
www.boschsecuritysystems.com
Pet Friendly
®
is a registered
trademark of Bosch Security
Systems in the United States.
© 2004 Bosch Security Systems
4998153065B
Page 3 of 10

Publicité

Table des Matières
loading

Table des Matières