Gas
Adjusting from liquid
supply
gas to natural gas
Nozzle burner 1
Full
Replace in compliance
flame
with Table 1
Regulating
Saving
needle 2
flame
Screw out slightly and
adjust the flame size
Attention! (A hint for the serviceman) The
adjustment of the cooker to another gas type
should be registered at the connection
place.
Issue and attach a label with the gas type
which the cooker has been adjusted to.
EN
Adjusting from natural
gas to liquid gas
Nozzle burners 1
Replace in compliance
with Table 1
Adjusting needle 2
Screw in against the
stop and check up gas
supply
Alimentation
Réglage du gaz
a gas
liquide au gaz naturel
Brûleur de buse 1
Flamme
Remplacer
complète
conformément au
tableau 1
Aiguille régulatrice 2
Flamme de
Dévisser légèrement
sauvetage
et ajuster la taille de
la flamme
Attention! (Un indice pour le réparateur)
Le réglage de la cuisinière sur un autre
type de gaz doit être enregistré sur le lieu
de raccordement.
Émettez et collez une étiquette indiquant le
type de gaz pour lequel la cuisinière a été
réglée.
FR
Réglage du gaz
naturel au gaz liquide
Brûleur de buse 1
Remplacer
conformément au
tableau 1
Aiguille régulatrice 2
Dévisser légèrement
et ajuster la taille de
la flamme