Télécharger Imprimer la page

Balboa 908 M3301 Mode D'emploi page 20

Masquer les pouces Voir aussi pour 908 M3301:

Publicité

Les langues disponibles

Les langues disponibles

Sensors are out of balance. if
alternating with spa temperature, it
5n5
may just be a temporary condition.
If flashing by itself, spa is shut
down.
A significant difference between
temperature
HFL
detected. This could indicate a
flow problem.
Continuous low flowing problem.
(Display on the fifth occurrence of
LF
HFL message within 24 hours) The
heater is shut down, but other
functions on SPA keep running.
Possible inadequate water, poor
flow, or air bubbles is detected in
dr
the heater. Spa is shut down for 15
minutes.
Inadequate
heater. (The third time for "dr"
dry
signal.)Spa is shut down.*
"Ice"-Potential freeze condition
1CE
detected.
Initial Start-up
When your spa is first actuated, it will go into priming mode, indicated by
last for less than 5 minutes (press "Temp" or "Set" to skip Priming Mode) and then the spa will begin to heat
the spa and maintain the water temperature in the Standard mode.
Temp/Set (80°F - 104°F / 26°C - 40°C)
The start-up temperature is set at 100F°/37°C. The last measured temperature is constantly displayed on the
LCD.
sensors
has
been
water
detected
in
(Ⅱ-2)、USA BALBOA control system :model GS100
GS100 (for two SPA massage pumps)
GS100 Control Reference Card
Non-Circ Operation
If the problem persists, please contact your distributor
or service group.
If the water level is normal, make sure all the pumps
have been primed. If the problem still exists, please
contact your distributor or service organization.
Follow action required for "HFL" message. Heating
capability of the spa will not reset automatically; you
may press any button to reset.
If the water level is normal, make sure all the pumps
have been primed. Press any key to reset. This
message will be reset within 15 minutes. If the
problem still exists, please contact your distributor or
service organization.
Follow action required for "dry" message. SPA will
not be reset automatically, press any key to reset it
manually.
Not action required. All the equipments will be
automatically activated regardless of spa status. The
equipment stays on 4 minutes after the sensors detect
that the spa temperature has arisen to 45°F/7.2℃ or
higher, An optional freeze sensor may be added to
protect
against
extraordinary
Auxiliary freeze sensor protection is advisable is
colder climates. See your dealer for details.
freeze
condition.
"
.The Priming mode will
- 19 -

Publicité

Chapitres

loading

Ce manuel est également adapté pour:

908 m332908 m351908 m357908 m360