7. Preset Filter Cycles
The first preset filter cycle begins 6 minutes after the spa is energized. The second preset filter cycle
begins 12 hours later. Filter duration is programmable for 2, 4, 6, or 8 hours or for continuous filtration
(indicated by FILC). The default filter time is 2 hours.
To program, Press "Warm" or "Cool", "then", "Jets 1". Press "Warm" or "Cool" to adjust. Press "Jets l" to
exit programming.
The first presetting filter cycle starts from 8AM and ends at 10AM.the second starts from 8PM and end at
10PM
For circulation systems, the circ pump and the ozone generator (if installed) run 24 hours. In hot
environments, the circ Pump may turn off for 30 minute periods, except during filter cycles. At the
beginning of each filter cycle all other equipments will run briefly to pure the plumbing.
8. Additional set for filter cycle.
Basically you do not need to set the filter cycle, but if you want, press "Time""Model/Prog" in turn in 3
seconds, then press "Mode/Prog" again, and SET START FILTER1 (AM) will show on panel. Press
"Warm" or "Cool" to reset the beginning and ending time of filter cycle.
When pressing "Mode/Prog", you will see "SET START FILTER1"then press "Warm" or "Cool" to make
the adjustment.
When pressing "Mode/Prog" you can see "SET START FILTER2(PM)"then press "Warm" or "Cool" to
make the adjustment.
When pressing "Mode/Prog" and you will see "SET START FILTER2"then press "Warm" or" Cool"
adjustment.
Finally, press "Mode/Prog" to make sure of the set.
9. panel lock and unlock
Press "Time","Blower" and "Warm" in turn within 3 seconds to lock the panel.
Press "Time", "Blower" and "Cool" in turn within 2 seconds to unlock the panel.
Signal Diagnosis on Display:
SIGNAL
SIGNIFICATION
No signal on display, and the
power has been cut off to the spa
- -
Temperature Unknown
"Over-heated"-the Spa has shut
down
0HH
.*one of the sensor has detected
118°F/47.8℃ at the heater
"Over-heated"-Spa has shut down
0H5
.*one of the sensor has detected the
spa water is 110°F /43.5℃.
Spa is shut down. *The "A" Jack
5nA
in the sensor is not working.
Spa is shut down. *The "B" Jack in
5nb
the sensor is not working.
REQUIRED OPERATION
The control panel will be disabled until power returns.
Spa setting will be preserved until next power up.
After the pump has been running for 2 minutes, the
current water temperature will be displayed.
Do not enter the water. Remove the cover and cool the
water. Once the heater has cooled, reset by pushing
any button. If spa does not reset, shut off the power to
the spa and call your dealer or service organization.
Do not enter the water. Remove the cover and cool the
water. At 107°F/41.7℃, the spa should automatically
reset. If spa does not reset, shut off the power to the
spa and call your dealer or service organization.
If the problem persists, please contact your distributor
or service organization (This might temporarily appear
when over-heating).
If the problem persists, please contact your distributor
or service group (This might temporarily appear when
over-heating).
- 18 -