Digital Compact Equipment Manual for Swimspa
EN
Assemble the pressure gauge. It is not necessary to use teflon tape, as a joint seals this point. Do
not use a tool to tighten the T-part of the pressure gauge, simply tighten it with your hands.
Water massage circuit
Connect the suction circuit of the massage pump to the Sump outlet of the Spa, placing two ball
valves to stop the water flow if necessary.
Connect the massage return to the Jets inlet of the Spa, placing two ball valves to stop the water
flow if necessary.
Jets 1
Sump 1
Jets 2
Sump 2
Massage
Massage
Puma 1
Puma 2
Air massage circuit
The piping of the air circuit should be fitted with a siphon 150 mm above the maximum water level of
the Spa, placing an anti-return valve between the this siphon and the Spa, as indicated in the
connection diagram.
5