Tectro TBH 570-3 Manuel D'utilisation page 146

Masquer les pouces Voir aussi pour TBH 570-3:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 68
3.
4
146
man_TBH570-3-TBH572-3 ('21) V1.indd 146
man_TBH570-3-TBH572-3 ('21) V1.indd 146
Off
The stove is off or switching off.
Fan
The stove is in preheating mode.
Load
The pellet supply is operating. LED 9 is also on (see figure 2)
Fire On
The stove is in the ignition phase.
On 1
The stove is on and burning at the lowest heat output level 1.
Eco
The stove has reached the set temperature.
StoP
The stove is in automatic brazier-cleaning mode. The flue
blower is running at maximum speed and the pellet supply
motor is running at its lowest speed.
Atte
This alert appears when an attempt is being made to start the
stove while it is cooling down.
4.2 STANDARD START-UP PROCEDURE
The brazier must be cleaned before each start-up. If the timer mode is
being used, the brazier must be cleaned before the automatic start-up.
The normal start-up and operating procedure is as follows:
1.
Make sure the combustion chamber is empty and clean.
2.
Make sure the stove door is closed.
3.
Fill the fuel hopper with good quality pellets.
4.
Push button 3 and hold for 2 seconds. The flue gas blower will start and the
hot rod igniter will come on. FAN ACC will appear on the display and LED 10
will light up to indicate that the igniter is in operation.
5.
After approx. 1 minute the display will show Load Wood. During this phase
the auger will transport the pellets from the fuel hopper to the combustion
chamber. The heat from the hot rod igniter will ignite the pellets.
6.
When the stove's required surface temperature has been reached, FIRE ON
will appear on the display. LED 10 will go out.
7.
The recirculation fan will start running and suck air in from the space behind
the stove. This will then be blown through the heat exchanger and heated
up. The heated air is blown into the space in front of the stove.
8.
During standard operation, the display shows the heat output level (1, 2, 3,
4 or 5) and the temperature of the room.
9.
When the required room temperature has been reached, ECO and the room
temperature will appear in the display. The stove will continue to burn at its
lowest heating level. If the SAVE mode is in operation, the stove will go out
automatically when the set temperature has been reached.
4.3 NON-STANDARD START-UP PROCEDURE
When the stove starts at a room temperature that is lower than around 0ºC or
when the combustion air is lower than 0ºC, the start-up procedure may be differ-
ent.
When the combustion procedure at these lower temperatures does not result in a
properly burning fire, the display will show "ALAr No FirE".
13-07-2021 13:38
13-07-2021 13:38

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tbh 572-3

Table des Matières