10. In the event of problems?

Problem
Massage head
rotates too slowly.
Massage head does
not move.
Heat function will
not switch on.

11. Technical data

Mains operation:
Input
Output
Average active efficiency
Efficiency at low load (10 %)
No-load power consumption
Dimensions
Weight
Battery:
Capacity
Nominal voltage
Type designation

12. Disposal

CAUTION
• The empty, completely flat rechargeable batteries must be disposed of through specially designated
collection boxes, recycling points or electronics retailers. You are legally required to dispose of the
rechargeable batteries.
• Remove the battery from the device by carefully opening the massager. To do this, unscrew all of
the screws on the housing with a screwdriver and remove the housing cover. Then take the battery
out of the device and dispose of it correctly.
• The codes below are printed on rechargeable batteries containing harmful substances:
Pb = Battery contains lead,
Cd = Battery contains cadmium,
Hg = Battery contains mercury.
For environmental reasons, do not dispose of the device in the household waste at the end of its
useful life.
Dispose of the device at a suitable local collection or recycling point.
Dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and
Electronic Equipment).
If you have any questions, please contact the local authorities responsible for waste
disposal.
The device battery must be disposed of separately. The battery must not be disposed of with
domestic waste.
Cause
The load on the massage head is too great.
Battery power is too low or device is not
connected to mains.
Device is not switched on.
Device has switched off automatically (auto-
matic switch-off).
The warming attachment is not on the massa-
ge head.
100-240 V~, 50/60 Hz, 0,8 A
9,0 V
≥ 88,68 %
≥ 87,88 %
≤ 0,044 W
45.5 x 10 x 15.5 cm
approx. 900 g
2600 mAh
7.4 V
Lithium-ion
Remedy
Free up massage head.
Charge the device.
Switch on the device.
Stop use and allow the device to
cool down.
Attach the warming attachment.
2,5 A, 22,5 W