Nieaf-Smitt Solar EazyPV Mode D'emploi Rapide page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

a.
Rpe voltage polarity. For AC voltages alternating + and – is shown
b.
Current clamp measurement active
c.
Rpe Null offset - indicates that testlead resistance offset is active
d. Caution – hot surface. If this icon appears, the EazyPV must be disconnected
immediately from the PV system until the icon is no longer shown on the LCD
e.
Solar module polarity indicator – indicates the polarity of the DC voltage applied
to the PV test terminals e.g. correct or reversed
f.
Caution – hazardous voltage detected
g.
Rpe test lock – active when continuous Rpe measurement has been enabled
h. Caution – refer to operating instruction. When this icon is active, the operating
instructions must be followed to avoid risk of danger
i.
Riso PASS/FAIL – indicates whether the measured insulation resistance is above or
below the factory set acceptable value
j.
Insulation Test Voltage selection – indicates the test voltage selected for insulation
resistance measurements
k.
Error – Refer to the specific error codes for further details
l.
STORE – LCD data is being stored in the onboard memory
m. RECALL – the data shown on the LCD has been recalled from the onboard memory
n. User Memory display – indicates the memory location of the results stored or
recalled on the LCD
o.
Voltage/current variation – indicates in the measured voltage and current values
deviate by more than or less than 5%
p.
Battery status icon
Solar
www.nieaf-smitt.com
23