Xylem PolluStat Instructions De Montage Et Manuel D'utilisation page 100

Compteur d'énergie thermique à ultrasons
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN 50310 (2011)
EN 1434-2 (2016)
1.4.2 Technical data pulse inputs
Pulse input class
Connecting cable length
Voltage supply
Source current
High level input threshold
Low level input threshold
Pull-up resistor
Pulse length
Pulse frequency
1.4.3 Possible combinations of the different input (class IB) and output (class OA) devices
Class OA
Class OB
Class OC
Class OD
Class OE
1.4.4 Setting up the three additional pulse inputs
The optional pulse inputs 1 + 2 + 3 for external meters can be set up using a suitable configuration software. You can configure
serial number, manufacturer, version (0 ... 255), medium code, input pulse value, unit and starting value of the external
meters.
1.4.5 Set-up possibilities
Pulse value
1
2,5
10
25
100
250
1000
Installation notes for pulse inputs:
It is important that the pulse cables not be affected by (or exposed to) an external voltage!
Check the polarity of pulse generators with "open collector" outputs.
The cable wires must not touch each other during installation, otherwise pulses will be counted in the instrument.
When setting up the meter it may be necessary to adjust the meter reading of the instruments connected and the pulse value
using a suitable configuration software.
For transmitting the values of the pulse inputs via radio, transmission must be set using a suitable configuration software, if
the meters were not already ordered with the transmission of these values set.
Page 100 of 108
Application of equipotential bonding and earthing in buildings with information
technology equipment
Heat Meters - Part 2: Constructional requirements
IB according to EN 1434-2:2016
1 m
+ 3 V DC
= 1,5 µA
U ≥ 2 V
U ≤ 0,5 V
2 MΩ
≥ 100 ms
≤ 5 Hz
Class IA
Class IB
yes
yes
yes
no
no
yes
no
no
no
no
Units
liters / kWh / pulse without unit
liters / kWh / pulse without unit
liters / kWh / pulse without unit
liters / kWh / pulse without unit
liters / kWh / pulse without unit
liters / kWh / pulse without unit
liters / kWh / pulse without unit
Article no.: 1080619046
Class IC
no
no
yes
yes
no
2020_07_27
Subject to technical change! Errors excepted.
Class ID
Class IE
yes
no
yes
yes
no
no
no
no
no
yes