Standard Values Of The Parameters - Tefcold BLC5-P Guide Rapide

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 83

20. STANDARD VALUES OF THE PARAMETERS.

Label
Value
Level
SEt
3
- - -
Pr2
- - -
Pr1
Hy
2.0
Pr1
AC
1
Pr2
PAU
0
Pr2
PFt
15
Pr2
Con
15
Pr2
COF
10
Pr2
rPo
0.0
Pr2
EPP
YES
Pr2
EPo
0.0
Pr2
i1P
YES
Pr2
i1o
0.0
Pr2
i2P
n
Pr2
i2o
0
Pr2
i3P
n
Pr2
i3o
0
Pr2
rEM
iPt
Pr2
CF
°C
Pr2
rES
dE
Pr2
Lod
rP
Pr2
rEd
rP
Pr2
d1P
cL
Pr2
odC
F-C
Pr2
doA
5
Pr2
dLc
Y
Pr2
rrd
Y
Pr2
d2F
EAL
Pr2
d2P
cL
Pr2
did
5
Pr2
oA1
tMr
Pr2
oA2
ALL
Pr2
oA3
Lig
Pr2
2CH
C1
Pr2
OAt
3
Pr2
OAS
0.1
Pr2
OAH
2.0
Pr2
OAi
rP
Pr2
OSt
0
Pr2
OSS
0.0
Pr2
OSH
2.0
Pr2
OSi
rP
Pr2
tdF
rE
Pr2
idF
06:00
Pr2
dtE
8
Pr2
MdF
20
Pr2
dFd
rt
Pr2
Fdt
0
Pr2
dAd
20
Pr2
FnC
c_n
Pr2
1592006207 XB570L GB r1.1 26.08.2015
Description
Set point
not used
Compressor hysteresis
Compressor restart delay
Time of stand by
Maximum acceptable duration of power failure
Compressor ON time with faulty probe
Compressor OFF time with faulty probe
Thermostat probe calibration
Evaporator probe presence
Evaporator probe calibration
Insert probe 1 presence
Insert probe 1 calibration
Insert probe 2 presence
Insert probe 2 calibration
Insert probe 3 presence
Insert probe 3 calibration
Probe selection to stop chilling cycle
Temperature measurement unit
Resolution (for °C):
Upper display view
View for rep
Door switch input polarity
Loads locked by door switch
Open door alarm delay
Cycle block with open port
Regulation restart after door open alarm
Second digital input function
Digital input polarity
Time delay for digital input alarm
Configuration of first auxiliary relay
Configuration of second auxiliary relay
Configuration of third auxiliary relay
Compressor setting during the holding
Second compressor switching on delay
Set point for second compressor
Differential for second compressor
Probe selection for second compressor
Auxiliary output timer
Output set point delta
Differential for auxiliary output
Probe selection for auxiliary output
Defrost type
Interval between defrost cycles
Defrost termination temperature
Maximum length for defrost
Temperature displayed during defrost
Drip time
Temperature display time after defrost
Fan operating mode during hold
-
XB570L
Range
-50.0 to 50.0°C
0.1 to 12.0°C
0 to 30 min
0 to 60 min
0 to 250 min
0 to 250 min
0 to 250 min
-12.0 to 12.0°C
n; Y
-12.0 to 12.0°C
n; Y
-12.0 to 12.0°C
n; Y
-12.0 to 12.0°C
n; Y
-12.0 to 12.0°C
iPt; rPt
°C; °F
in; dE
rP;EP
rP; EP; tiM; i1P; i2P; i3P
OP; CL
no; FAn; CP; F-C
da 0 a 254 min, 255=nu
n; Y
n; Y
EAL; bAL, ACy
OP; CL
0 to 255min
ALL; Lig; AUS; C2; tMr
ALL; Lig; AUS; C2; tMr
ALL; Lig; AUS; C2; tMr
C1; C2; 1C2
0 to 255 min
-50.0 to 50.0°C
-12.0 to 12.0°C
rP; EP; i1P; i2P; i3P
0 to 255 min
-50.0 to 50.0°C
-12.0 to 12.0°C
rP; EP; i1P; i2P; i3P
rE; in
0.1 to 24h00min
-50.0 to 50.0°C
0 to 255 min
rt; it; SET; dEF
0 to 60 min
0 to 120 min
o-n; C1n; C2n; Cn; o-Y; C1Y;
C2Y; Cy
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Blc10-pBlc14Blc3-p

Table des Matières