3.2.2 Assembling the flexible drive

Start up the motor (see Chapter 3.3).
X
Press the lock button located at the flexible drive's upper coupling manu-
X
ally (Diag. 3, pos. b).
Now push the flexible drive coupling into the shearing plant's coupling
X
sleeve and then position this by means of slight pressure upwards until
the lock button engages in the hole (Diag. 3, pos. c).
3.3

Switching the shearing plant on / off

CAUTION!
Make sure that the ventilation holes are always clear (Diag. 2+3,
pos. a). The shears drive remains switched off after the connec-
tion to the power supply. The shearing plant is switched on and
off respectively via the cord / lever (Diag. 2, pos. b). The drive is
switched on by means of one downward pull, and is switched off
again by repeating this operation.
Should the power supply be interrupted whilst the drive is running,
for safety reasons the motor switches off automatically, which
means that the unit must be switched on again via the cord / lever
when the power supply is re-established.
4

Maintenance

4.1

Cleaning

Before commencing any maintenance work disconnect the electrical power
supply by pulling out the plug!
Remove any oil and dirt from the shearing plant by means of a dry cloth. Do
not use liquids!
4.2

Service

WARNING!
For safety reasons the portable shearing plant should be subjec-
ted to an annual inspection. It is important that the self-tensioning
belt is checked periodically, since the functionality of the patented
safety cut-out device is dependent on this.