Environmental Protection And Waste Disposal; Introduction - Heiniger ONE Traduction De La Notice Originale

Masquer les pouces Voir aussi pour ONE:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
Malfunction
Motor always switching
off.
Motor system does not
switch off by lock up.
Shearing unit is noisy or
vibrates.
Motor gets hot.
Shearing plant cannot
be switched off.
6

Environmental protection and waste disposal

6.1

Introduction

The operator bears the responsibility for disposing of the machine in the
proper manner. Observe the relevant regulations applicable in your coun-
try.
12
Cause
Cutter blocked.
Mechanical damage in
the shearing handpiece
or flexi-shaft.
Reverberation sensor's
magnet faulty.
Faulty reverberation
sensor.
Power supply too weak.
Control unit faulty.
Faulty motor bearing.
Faulty motor bearing.
Ventilation screen dirty.
Malfunctions in the rigid
drive downtube / flexible
drive and / or shearing
handpiece.
Switch faulty.
ONE Shearing Plant – Translation of the original instructions
Rectification
Remove blockage.
For the purposes of fault
finding first of all uncouple
the shearing handpiece
and restart the plant. If the
fault persists, uncouple
the rigid drive downtube
or flexible drive from the
shearing plant. Rectify any
damage.
If the fault still persists,
then have the shearing
plant repaired.
Have the insulation flange,
inc. magnet, replaced.
Have the reverberation
sensor replaced.
Check the power supply.
Have control unit replaced.
Have the motor replaced.
Have the motor replaced.
Clean ventilation screen.
Have fault rectified.
Have the switch replaced.

Publicité