Operating Instructions

Forced operation

Forced operation is used when the remote controller can't be used. The operation will be started if the ON/OFF
button is pressed. If you want to stop the operation, re-press the button.
Operating mode
Indoor FAN Speed
Setting Temperature

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature
and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller
sets. If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1
'beep'. If you want to stop the operation, re-press the button.

Auto Restart Function

This function is useful in the situation of power failure.
When power regains after a failure this feature restore the previous operating condition
and the air conditioner will run in the same settings.
NOTE
This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6
seconds. The unit will beep twice and the lamp will blink 8 times.
To enable it, press the button again for 6 seconds. The unit will beep twice and the blue lamp will blink 4 times.
18 Multi zone
[Ceiling Cassette Type]
Forced Operation
Button
Room Temp. ≥ 24°C(75.2°F) 21°C(69.8°F) ≤ Room Temp. < 24°C(75.2°F)
Cooling
High
22°C(71.6°F)
Heat pump Model
Healthy Dehumidification
High
23°C(73.4°F)
Room Temp. < 21°C(69.8°F)
Heating
High
24°C(75.2°F)