Output elements
Do not strike the shaft or bearings of the motors.
Do not exceed the permissible axial and radial forces on the shaft end stated
in the configuration specification.
Axial forces are not permitted on motors with an integrated brake.
Suitable devices should always be used to push on or pull off the output elements (e.g. the
coupler, gear wheel, belt pulley, Fig. 4).
-
Use the tapped hole in the shaft end.
-
Heat up the output elements if necessary.
-
Use a shim to protect the centering in the shaft end when pulling output elements off.
-
If necessary, fully balance the motor with the output elements according to ISO1940
Fig. 4 Pulling off and putting on output elements.
A
Shim (protects the centering in the shaft end)
5

Electrical connections

5.1

Important instructions

Siemens AG
Electric shock hazard!
When the rotor is rotating, the motor terminals carry a voltage of
up to approx. 300 V.
Stop the motor before commencing any electrical work.
Only use trained, qualified personnel for assembly work on the
converters and plugs.
Observe the regulations for working in electrotechnical plants.
Do not plug or unplug any connectors unless they are in a de-
energized condition.
ENGLISH
NOTICE
A
DANGER!
610.40 075.21