(1) Install the indoor unit temporarily.
• Fix the hanger to the hanging bolt.
Make sure to securely fix the hanger with the nut and
the washer for hanger (3) from the upper and lower
side. (Refer to Fig. 7)
If the washer clamp (7) is used, the upper side washer
for hanger (3) may be protected from falling off.
(Refer to Fig. 8)
[To fix hanger]
Nut
(Field supply)
Fig. 7
[Washer clamp (7) fixing method]
Washer clamp (7)
(accessory)
Insert
Fig. 8
(2)
• The installation pattern paper (5) is matched to the ceil-
ing opening dimension.
For the height of ceiling lower surface from the floor
level, confirm with the builder of ceiling.
• The center of the ceiling opening is shown in the instal-
lation pattern paper (5).
The center of the indoor unit is indicated as triangle
marks on the sides and bottom of the unit and those on
the installation pattern paper (5).
• Put the installation pattern paper (5) to the indoor unit
with four screws (6).
At this time, put the installation pattern paper (5) to the
indoor unit with the triangle marks on the indoor unit
and those on the installation pattern paper (5) aligned.
Center of the
indoor unit
Center mark
of the unit
Screw (6)
(accessory)
[Installation of the installation pattern paper]
< Installation work after the ceiling work is finished >
3P161684-7N
English
Hanging bolt
Washer for hanger (3)
(accessory)
Hanger
Tighten the nut
(double nut)
Upper side nut
Center of
ceiling opening
Installation
pattern
paper (5)
(accessory)
Screw (6)
(accessory)
(3) Adjust so that the unit will be properly positioned.
(Refer to 3. PREPARATION BEFORE INSTALLATION
– (1))
• Using the Installation guide (15) allows you to check
the positions from the underside of the unit to the lower
ceiling surface.
Lower ceiling
surface
Installation guide (15)
(4) Check the level of the unit. (Refer to Fig. 9)
(5) Remove the washer clamp (7) used for preventing the
washer for hanger (3) from dropping and tighten the up-
per side nut.
(6) Remove the installation pattern paper (5).
Level
[Maintaining horizontality]
Fig. 9
CAUTION
• Install the indoor unit leveled.
If the indoor unit is inclined and the drain piping side gets
high, it may cause malfunction of a float switch and results
in water leakage.
• Attach nuts on the upper and lower side of hanger.
If there is no upper nut and the lower nut is over-tightened,
the hanger and the top plate malfunction and create un-
wanted noise.
• Do not insert materials other than those specified
into the clearance between the hanger and the
washer for hanger (3).
Unless the washers are properly attached, the hanging
bolts may come off from the hanger.
WARNING
The indoor unit must be securely installed on a
place that can withstand the mass.
If the strength is insufficient, the indoor unit may fall
down and cause injuries.
Apply the short
side of the
cut-out section.
Underside
of the unit
Vinyl tube