DAILY CHECK AND MAINTENANCE
A daily check of the pallet truck can help
prevent accidents. Give special attention to
the wheels (127), the axles (109), the handle
(H101), the forks and control lever (H106). The
forks should be unloaded and lowered in the
lowest position when the job is completed.
LUBRICATION
Use motor oil or grease to lubricate all
moveable parts.
GENERAL MAINTENANCE
1. Please check the oil level every six
ENTER TECHNICAL PARAMETER MODE
1. Press ZERO and TARE keys at the same
2. Press TARE key until display shows "PROG"
3. Press in order M+, U and TARE keys
4. Press TARE key to select parameter, press
5. It may be necessary to use TARE key to
CALIBRATION
1.
2. Press the TARE key until display shows
PAGE 15 OF 62
months. The volume of oil is about
10.1 fl. oz.
NOTE: Must use 10% of capacity to
calibrate.
time. The display shows "F1 UNIT".
and press ZERO key to show "PN" on the
display.
to enter technical parameter setting
mode.
Zero key to enter value and U key to exit.
set a value or use M+ and PT keys to
move the active digit.
Enter Technical Parameter Setting
mode(see steps 1-3 above) until display
shows "P1 rEF".
"P2 CAL". Press ZERO key to enter and
press TARE key until display shows "CAL".
MAINTENANCE
2. Use the hydraulic type oil according to
temperature scale below.
Temperature
-5°C ~ +45°C L-HM68 Hydraulic
-15°C ~ -5°C
EXPEL AIR FROM THE PUMP UNIT
Air may get into the hydraulics due to
transportation or pump disturbances. It can
prevent forks from elevating while pumping
in ASCENT position. To expel air: Put the
control lever (H106) to the LOWER position,
then move the handle (H101) up and down
several times.
CALIBRATION
3. Press ZERO key twice and display shows
"UNLD". Remove all weight from the forks.
After STABLE indicator is visible, press the
ZERO key.
4. The display shows the calibration weight
value. Use the M+, PT and TARE keys to
set the weight value.
NOTE: Use M+/PT keys to move
active digit, use TARE key to
change value. Also you can also
press G/N to make value zero.
5. After weight is keyed, press ZERO key to
enter. Display will show "LOAD".
6. Add calibration weight onto forks. After
STABLE indicator is visible press ZERO key
to enter.
7. Display returns to normal once
calibration is successful. If an error
message is shown, try the calibration
steps again; a disturbance may have
prevented a successful calibration. If the
problem persists, please contact Uline
Customer Service.
Oil
oil (equivalent to ISO VG68)
L-HM46 Hydraulic
oil (equivalent to ISO VG46)
0522 IH-1679