Unauthorised Modification And Spare Parts Production; Impermissible Operating Modes; General Aspects; Affiliation - SFA SANICUBIC SC Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31

1.7 Unauthorised modification and spare parts production

Modifications or changes to the machine shall be permissible only after consultation with the
manufacturer. Original spare parts and accessories authorised by the manufacturer serve to
ensure safety. The use of other parts may results in the loss of liability for the consequences
that may occur.

1.8 Impermissible operating modes

The operational safety of the machine supplied is ensured only when used as intended
according to Section 2-General aspects of the operating instructions. The threshold values
indicated in the data sheet must by no means be exceeded.

2. GENERAL ASPECTS

2.1 Affiliation

These operating instruction are valid for the sewage lifting units of the SANICUBIC
In case of non-observation to the operating instructions - in particular the safety instructions
- as well as unauthorised modification of the device or the installation of non-original spare
parts the warranty claims will automatically become void. The manufacturer assumes no lia-
bility for any damage resulting from this!
As any other electrical appliance, this product can also fail due to missing main power or a
technical defect. If a damage can occur as a result, an emergency power generator, a man-
ual membrane pump, a second system (double system) and/or a mains-independent alarm
system should be planned according to the application. We as manufacturers will be happy
to advise you also after the purchase. In case of defects or damages, please get in touch with
your dealer.
Products in the range :
SANICUBIC
1 SC3.0 T
®
SANICUBIC
1 SC4.0 T
®
SANICUBIC
1 SC5.5 T
®
SANICUBIC
1 SC7.5 T
®

2.2 Inquiries and purchase orders

Please send your inqueries and orders to your specialist dealer.

2.3 Technical data

Single systems:
Type
SANICUBIC
1 SC3.0 T
®
SANICUBIC
1 SC4.0 T
®
SANICUBIC
1 SC5.5 T
®
SANICUBIC
1 SC7.5 T
®
6
SANICUBIC
SANICUBIC
SANICUBIC
SANICUBIC
Input
Nominal
Voltage
Power
Power
U [V]
P1 [kW]
P2 [kW]
4.0
3.0
400
5.5
4.0
400
6.3
5.5
400
8.7
7.5
400
2 SC3.0 T
®
2 SC4.0 T
®
2 SC5.5 T
®
2 SC7.5 T
®
Rated
Speed
current
(50 Hz)
I
[A]
[min
]
-1
MAX
6.9
1400
11.2
1400
12.1
1400
16.9
1400
SC series.
®
Feed
Pumping
Pressure
volume
head
connection
[m
/h]
[m]
3
130
10
DN 100
140
13
DN 100
160
18
DN 100
165
22
DN 100

Publicité

Table des Matières
loading

Table des Matières