Analyse combustion gases and check that the emission values are
correct at least once a year, in compliance with current law.
Check the fuel filter: if it is dirty, replace it.
Check that all the components of the combustion head are in a
good state, not deformed by the temperature and free from im-
purities or deposits from the installation environment or by poor
combustion and check also the electrodes are working efficiently.
If the combustion head needs to be cleaned, remove the compo-
nents following the procedure indicated below:
Disconnect the light oil 1 pipes from the connectors beneath the
combustion head (be careful of drips)
Unscrew screws 2(four) and turn the burner around pin 3 in
thehinge (figure 1).
After pulling out the ignition cables 4 from their electrodes,
completely unscrew the locking nuts 5 (two) from mixing unit
(figure 2).
Lift up the mixing unit 6 (figure 3) until the pipes some out and
then pull the unit out completely in the direction indicated by
the arrow 7 in figure 4.
To complete the maintenance operations proceed with the
reassembly of the mixing unit by carrying out the above
operations in reverse order, after checking the ignition
electrodes and the deflector disk are correctly positioned ( See
0002935131).
On closing the burner, gently pull towards the electrical panel,
!
putting them slightly in tension, the two ignition cables, and
then arrange them in their places (7) as in figure 2. This will
ensure that the two cables do not get damaged by the fan
during the working of the burner.