Operating Instructions and Parts Manual

Installation

eLectrIcaL data
Overheating, short-circuiting and fire damage will result
from inadequate wiring.
Check motor data plate voltage compatability. The cord must only plug into
a grounded outlet and may require a new cord and plug that complies to
national requirements and local codes for your area.
groundIng InstructIons
This product must be grounded. In the event of an electric short circuit, grounding
reduces the risk of electrical shock by providing an escape wire for the electric current.
Unit is equipped with a cord that has a grounding prong.
Improper use of grounding plug can result in a risk of
electrical shock.
NOTE: Do not use grounding adapter.
When converting to an alternate voltage, be sure the green
ground wire of the cord connects to the ground pin of the plug
and to the metal body of the pressure switch.

Operation

MoIsture In coMPressed aIr
Moisture in compressed air will form into droplets as it comes from an air
compressor pump. When humidity is high or when a compressor is in continuous
use for an extended period of time, this moisture will collect in the tank. When using
a paint spray or sandblast gun, this water will be carried from the tank through the
hose, and out of the gun as droplets mixed with the spray material.
ImPortAnt: This condensation will cause water spots in a paint job, especially
when spraying other than water based paints. If sandblasting, it will cause the sand
to cake and clog the gun, rendering it ineffective.
A filter in the air line, located as near to the gun as possible, will help eliminate this
moisture.

BeFore FIrst start-uP Break-In Procedure

Complete this procedure before using compressor for the first time. Once completed,
it is not necessary to repeat.
1. Ensure ON/OFF switch is in the "OFF" position. Open drain valve on side of tank
by turning drain knob counter-clockwise.
2. Plug in power cord.
3. Press ON/OFF switch and run compressor for 30 minutes.
4. Press ON/OFF switch to turn unit off.
5. Close drain valve on side of tank.
The compressor is now ready for use.

BeFore each start-uP oPeratIng Procedure

1. Turn regulator knob fully counterclockwise (to the left) to close air flow.
2. Connect air hose to outlet of regulator.
3. Press ON/OFF and let compressor run until it reaches automatic shutoff pressure.
4. Attach tire chuck or tool to end of hose.
5. Turn regulator knob clockwise (to the right) to desired pressure of tool being used.
Grounding
Pin
Figure 11
Open
Drain
Knob
Figure 12 - drain valve
Outlet
Gauge
Regulator
Knob
Figure 13 - control Panel
www.chpower.com
WL675000
Grounded
Outlet
Close
ON / OFF
Switch
11