INTRODUCTION
Wire Specifi cations
Use this chart to pull wires in preparation of your installation.
DESCRIPTION OF WIRE RUN
Power Wire, secondary DC output
Local Area Network (LAN)
CAT 5/6 Network Cable
Door Strike/LiftMaster Gate Operator
Magnetic Lock
Dry Contact Closure (Most Gate Operators)
Exit Request (REX)
Supervised Input
Wiegand/Proximity Readers
NOTE: Main power supply and control wiring MUST be run in separate conduits. Conduits must be UL approved for low and high
voltage. Refer to the NEC, ANSI/NFPA 70 for additional wiring requirements.
NOTE: Place the CAP2D unit within 500 feet of its associated electronic strike or latch. Monitoring Software is not UL evaluated.
Always provide power from a dedicated source. Plug provided transformer into an outlet wired to its own 10 Amp minimum circuit
breaker. This will prevent two problems:
• Other equipment cannot introduce spikes, noise, surges or dips into the power circuit that will affect the system.
• The system's operation will not be affected if any other equipment develops a short circuit across the power line.
* CAT 5/6 NETWORK CABLE NOTES:
• For outdoor distances exceeding 140 feet (42.7 m), a UL497 compliant primary surge protector MUST be installed at
the controller.
• Distances exceeding 328 feet (100 m) can be accommodated with additional hardware. Contact Technical Support for more
information. Additional hardware was not evaluated under UL294.

PRE-INSTALL

WIRING
NETWORK
WIRE SPECIFICATION
2-Conductor 14 AWG
2-Conductor 16 AWG
2-Conductor 18 AWG
8-Conductor, 24 AWG Twisted pair
2-Conductor 18-22 AWG Shielded
2-Conductor 18-22 AWG
2-Conductor 18-22 AWG Shielded
2-Conductor 18-22 AWG
2-Conductor 18-22 AWG
7-Conductor 18-22 AWG Shielded
7
ACCESS CONTROL
MAXIMUM RUN DISTANCE
Up to 60 feet (18.3 m)
Up to 37 feet (11.3 m)
Up to 24 feet (7.3 m)
328 feet* (100 m)
100 - 250 feet (30.5 - 76.2 m)
50 - 125 feet (15.2 - 38.1 m)
500 - 2500 feet (152.4 - 762 m)
500 feet (152.4 m)
500 feet (152.4 m)
500 feet (152.4 m)
INSTALL

Publicité