Ripple & Noise
(20MHz bandwidth):
Transient Response:
Temperature Coefficient:
Status Indication:
METER SPECIFICATIONS (Main Outputs)
Meter Types:
Meter Resolutions:
Meter Accuracies:
AUXILIARY LOGIC OUTPUT (EX354RT only)
Voltage:
Meter Voltage Accuracy:
Current Limit:
Output Protection:
Load Regulation:
Line Regulation:
Ripple & Noise
(20MHz bandwidth):
Transient Response:
Temperature Coefficient:
Status Indication:
GENERAL
AC Input:
Power Consumption:
Operating Range:
Storage Range:
Environmental:
Safety & EMC:
Size:
Weight:
Typically <2mVrms, <10mVpk-pk, constant voltage mode.
<200µs to within 50mV of set level for a 5% to 95% load change.
Typically <100ppm/°C.
Output on lamp. Constant current mode lamp.
Dual 4 digit meters with 14mm (0·56") LEDs. Reading rate 4 Hz.
10mV, 1mA.
Voltage 0.3% of reading ± 3 digits,
Current 0.5% of reading ± 3 digits.
Variable <1.5V to >5V by front panel control.
0.3% ± 4 digits
5A minimum.
Output will withstand up to 7V forward voltage.
Diode clamp reverse protection for currents up to 3A.
<0.5% for 90% load change.
<0.1% for 10% line voltage change.
Typically <2mVrms, <10mVpk-pk (CV mode).
Typically <200µs to within 50mV of set level for a 5% to 95% load
change.
Typically <100ppm/ºC.
UNREG lamp.
110V - 240V AC ± 10%, 50/60Hz. Installation Category II.
500VA max.
+5ºC to +40ºC, 20% to 80% RH.
−40ºC to + 70ºC.
Indoor use at altitudes up to 2000m, Pollution Degree 2.
Complies with EN61010-1 & EN61326-1.
For details, request the EU Declaration of Conformity for this
instrument via http://www.aimtti.com/support (serial no. needed).
260 x 160 x 320mm (WxHxD).
4.3kg