TESTING AND CHECKING
Make sure the general safety precaution "WARNINGS" has been carefully observed.
● Release the gearmotor with the proper release key.
● Make sure the gate can be moved manually during opening and closing phases with
a force of max. 390N (40 kg approx.)
● Lock the gearmotor.
● Using the Key selector switch, push button device or the radio transmitter, test the
opening, closing and stopping of the gate and make sure that the gate is in the
intended direction.
● Check the devices one by one (photocells, flashing light, key selector, etc.) and
confirm the control unit recognizes each device.
E

RECOGNITION OF LED

LED Indication
LED1 Photocells LED1 will be on when the first pair of the photocells are activated.
LED2 Photocells LED2 will be on when the second pair of the photocells are activated.