Cleaning/replacing the foam filter of the pre‐filter 
Prerequisite 
 The pre‐filter has been removed. (→ Removing the 
pre‐filter) 
How to proceed: 
 T 
1. Press in the engagement hooks on the pre‐filter 
and pull off the housing. 
2. Remove the pre‐filter pipe and foam filters.
– BioMaster 250: 4 foam filters.
– BioMaster 350: 5 foam filters.
– BioMaster 600: 6 foam filters.
3. Rinse the foam filters in warm water. If necessary,
replace the foam filters. 
4. Assemble the pre‐filter in the reverse order.
Cleaning/replacing the filter media 
 U 
Filter media on delivery: 
 
Foam filter 30 ppi 
Foam filter 20 ppi 
Hel‐X bio‐elements, always place them contained 
in the bag into the strainer casing 
Prerequisite 
 The unit head is removed. (→ Dismantling the unit 
head) 
How to proceed: 
 U 
1. Remove all filter baskets.
2. Clean the filter baskets and container.
3. Rinse the filter media in warm water. If necessary,
replace the filter media. 
4. Place the parts into the container in the reverse or‐
der. 
– Carefully fit the filter baskets  in the bottom re‐
cess in the container. Correctly position the pre‐
filter.
5. Reassemble the unit in the reverse order.
 
Cleaning/replacing the impeller unit 
Prerequisite 
 The unit head is removed. (→ Dismantling the unit 
head) 
How to proceed: 
 V 
1. Turn the pump lid counter‐clockwise (bayonet lock) 
and remove. 
2. Remove the impeller unit and clean. If necessary, re‐
place. 
3. Fit the impeller unit, replace the pump lid and lock 
(turn clockwise). 
– Ensure that the two rubber bearings are correctly
seated. 
4. Reassemble the unit in the reverse order.
 
Cleaning the valve box of the pre‐filter 
The valve box only has to be cleaned if venting does 
not function even though the foam filters of the pre‐
filter have been cleaned. 
 
Prerequisite 
 The pre‐filter has been removed. (→ Removing the 
pre‐filter) 
How to proceed: 
 W 
1. Undo the fasteners and pull off the valve box.
– If  necessary,  carefully  lift  the  fasteners  using  a
screwdriver. 
2. Remove the valve seal and both valve flaps. Clean 
all parts. 
3. Assemble the valve box in the reverse order.
– Ensure  that  the  fitted  valve  flaps  can  be  easily 
moved. 
– Note: Ensure that the opening in the valve seal is
precisely  aligned  to  the  opening  in  the  suction 
chamber.
Cleaning the suction chamber of the pre‐filter 
The suction chamber only has to be cleaned if venting 
does  not  function  even  though  the  foam  filters  and 
valve box of the pre‐filter have been cleaned. 
 
Prerequisite 
 The pre‐filter has been removed. (→ Removing the 
pre‐filter) 
C A U T I O N  
There is a strong spring in the suction chamber that 
can act like a projectile. 
Risk of injury due to parts flying around 
 When opening the suction button, do not point it at 
persons. 
 Firmly hold the suction button.
How to proceed: 
 X 
1. Press in the engagement hooks, hold and turn the 
locking ring counter‐clockwise (bayonet lock). 
2. Carefully lift the suction button until the tension of 
the spring is relieved. 
3. Remove the suction button and spring. 
4. Clean the suction chamber.
5. Assemble the suction chamber in the reverse order.
 