N O T E  
The following applies to all units with heater: 
 Adhere to the rules for careful handling. (→ Careful
handling of the heater) 
Careful handling of the heater 
C A U T I O N  
Hot surface! 
Risk of burns when touching the glass bulb. 
• Unplug the heater and allow it to cool down be‐
fore removing it from the water.
C A U T I O N  
Risk of breaking the glass! 
The glass bulb of the heater can break and cause cuts. 
 Take care when handling the heater.
 Allow the heater to cool down first. Do not immerse 
it in cold water or pour cold water over it. 
• Take care of glass fragility when installing the
heater in the adapter or the opposite operation
Removing the heater 
The heater has to be removed for cleaning and mainte‐
nance, and for removing the unit head. 
How to proceed: 
 C 
1. Hinge up the handle.
2. Unscrew the holding ring together with the heater
counter‐clockwise. 
Fitting the heater 
How to proceed: 
 D 
1. Screw  the  holding  ring  with  heater  clockwise  into 
the threaded hole. 
– To exchange the heater: Moisten the glass bulb
with water and push the heater into the holding
ring as far as it goes. 
2. Place  the  power  connection  cable  into  the  cable
guide. 
3. Hinge the handle down.
 
Removing the connection unit 
The heater has to be removed for cleaning and mainte‐
nance, and for removing the unit head when hoses are 
connected. 
 
How to proceed: 
 E 
1. Push the lever to the "UNLOCK" position. 
– The lever can only be moved when the pre‐filter
is locked. 
– The inlet and outlet are closed.
2. Remove the connection unit. 
 
Fitting the connection unit 
How to proceed: 
 F 
1. Fit  the  connection  unit  and  push  it  into  the  unit 
head as far as it goes. 
– Ensure that the ridges on the connection unit are 
correctly  aligned  to  the  recesses  on  the  unit 
head. 
2. Push the lever in the direction "LOCK".
– The inlet and outlet are open.
Removing the pre‐filter 
It  has  to  be  removed  for  cleaning  and  maintenance 
and for removing the unit head. 
Prerequisite: 
 The  inlet  and  outlet  are  closed.  (→ Removing  the 
connection unit) 
How to proceed: 
 G 
1. Push the lever to the "UNLOCK" position. 
– The lever can only be moved when the inlet and 
outlet are closed. 
2. Pull out the pre‐filter.
 
Fitting the pre‐filter 
How to proceed: 
 H 
1. Fit the pre‐filter into the opening and firmly push it
into the unit head as far as it goes. 
– Ensure that the ridges on the pre‐filter are cor‐
rectly aligned to the recesses on the unit head. 
2. Push the lever to the "padlock closed" symbol.
– The pre‐filter is locked.