System Start Up Procedure

Step 1 -
Turn on main water supply to home.
Step 2 -
Open inlet isolation valve to the ¼ open position.
Step 3 -
Press the red pressure relief button on top of filter
housing lid to bleed air from the system while it is filling with
water. Stop pressing pressure relief button once water flow from
pressure relief is visible.
Step 4 -
Fully open inlet and outlet isolation valves and allow
water to flow from hot and cold side of faucets until all air has
been purged from the plumbing system.
Step 5 -
Check for leaks and repair as needed.
Step 6 -
Close hot side faucet and allow water to flow from
cold side faucet at full flow for 10 minutes to properly flush new
filter cartridge to prepare it for use. Turn off faucet cold side.
Step 7 -
Turn on water heater(s)
The system is now ready for use.
NOTICE
Check frequently over the next 24 hours to ensure no leaks are
present

Volumetric Flow Monitor Operation

The flow monitor and inline flow meter that comes with this sys-
tem is a volumetric flow device that records water volume usage
and sounds an alert when the filter cartridge has reached its
rated gallon capacity.
IOM-WQ-BB-S100
2130
Flow Wave Indicator- Indicates water flow
through system.
Low Battery Indicator- Alarm Icon illuminates
when battery power is low and alarm will
sound. Replace batteries to clear alarm
conditions.
WARNING
!
Change Batteries ONLY when screen is dor-
mant and NO water is flowing through the
flow meter. If water is flowing and screen is on
when batteries are changed, the last usage
volume will not be saved.
Battery Compartment- 2- AA Alkaline
Batteries.
Display/Reset Button- Can be pressed for 1
second while display is dormant to view gal-
lons remaining. Press and hold for 6 seconds
to reset display back to 84480 Gallons and
to clear alarm after filter cartridge is changed.
Volume Remaining- Counts down from full
capacity to "0" gallon. Full Capacity is 84480
Gallons. Audible alarm will sound and screen
will flash "0 gal" when filter cartridge change
is required.
Display Screen- Activates only when water is
flowing through system. Display is dormant
after 10 seconds of no water flow.
EDP# 68110146