Connect Green Tube
Step 7
Locate the 1/4" green tube in the box. Insert one open end of the green 1/4" tube
to the open 1/4" quick connect elbow fitting above the "FIVE MICRON SEDIMENT
FILTER" label making sure the tube is pushed in all the way passed the o-ring to
the tube stop.
Insert the other open end of the green 1/4" tube into the
Step 8
open 1/4" quick connect fitting on the plastic adapt-a-valve
making sure the tube is pushed in all the way passed the
o-ring to the tube stop.
Connect Blue Tube
Step 9
Locate the 1/4" blue tube attached to the faucet. Insert the open end of the blue 1/4"
tube into the open 1/4" quick connect elbow fitting above the "CARBON BLOCK
PRE-FILTER" label making sure the tube is pushed in all the way passed the o-ring
to the tube stop.
System Start Up
Warning: To prevent the possibility of electrical shock, clean up any water on
cabinet floor and dry all water from outside of unit.
Turn on the incoming cold water at the angle stop valve
Step 10
and the Adapt-a-Valve. Check the system for leaks and
tighten any fittings as necessary. (Check frequently over
the next 24 hours to ensure no leaks are present).
Step 11
Turn faucet handle to the open position to start the flow of water through the unit.
Run 7 gallons of water through the unit in order to flush out the normal black carbon
fines (it will "sputter" until the air is purged out) from the unit. Initially, the water may
appear cloudy which is due to tiny air bubbles and it will clear up shortly. Close the
faucet when finished.
Check for leaks. If you have any leaks, shut off the water supply to your system,
tighten any fittings / housings and restart unit.
Step 12
Plug the (24 volt) transformer power cord connector into the UV module wire harness
connector and plug the transformer into an electrical outlet. The white UV end cap
will light up when in service (Plugged in).
All manuals and user guides at all-guides.com
7
Green Tube
Adapt-a-Valve
ON