Performance Data Sheet - Watts Big Bubba Manuel D'installation, D'utilisation Et D'entretien

Une solution complète de système pour toute la maison pour la réduction du plomb, des pfoa/pfos (substances perfluoroalkylées), des kystes, et du goût et de l'odeur de chlore
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Performance Data Sheet

Certified Substance Reduction
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Depending on incoming feed water conditions, replacement gallon capacity
may vary.
Description
Big Bubba BB-S100 Complete Whole Home Solution for the Reduction of
Lead, PFOA/PFOS, Cysts, and Chlorine Taste & Odor
System Model/Part Number
BB-S100 / 7100976
Capacity
84,480 Gallons / 319,791 Liters
Replacement Filter Cartridge
Carbon Block Filter Cartridge for the Reduction of Lead, PFOA/PFOS, Cysts,
and Chlorine Taste & Odor Model Number BB-C100 / Part Number 7100980
Minimum/Maximum Operating Water Temperature
34 to 125°F / 1 to 52°C (125°F / 52°C at 80psi maximum pressure)
Minimum/Maximum Water Pressure
25psi to 125psi /1.75 Kg/cm2 to 8.78 Kg/cm2
Rated Service Flow
4 GPM (15 LPM)
Pressure Drop of System at Rated Service Flow
10psig
BB-S100 system has been certified by IAPMO R&T against NSF/
ANSI 42 and 53 for the reduction of substances listed below. The
concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/
ANSI 42 and 53. The system is certified to CSA B483.1 and NSF/
ANSI 372 for Lead Free compliance.
Treated water from system should be tested at regular intervals to
ensure quality and safety at point of use.
SUBSTANCE
AVERAGE INFLUENT
NSF/ANSI 42 — Aesthetic Effects
Chlorine
NSF/ANSI 53 — Health Effects
Cyst
Lead pH 6.5
0.15 mg/L ± 10%
Lead pH 8.5
0.15 mg/L ± 10%
PFOA/PFOS
.0015 mg/L ±10%
Not all water will contain contaminants listed. Testing performed under standard laboratory conditions; actual performance may vary. Filter system usage must comply with all state and
local laws. Filter system is only to be used with cold water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. Flush new filter cartridge for 10 minutes to prepare it for use. Spent
adsorption media shall not be regenerated and used.
Non-Certified Substance Reduction*
SUBSTANCE
Chlorine
Chloramine
*Claims are not performance tested or certified by IAPMO. Performance claims are based on independent laboratory and manufacturer's internal test data.
Actual performance is dependent on influent water quality, flow rates, system design and application. Results may vary.
Refer to Owner's Manual and Installation instructions for installation, operation, maintenance, and warranty information.
IOM-WQ-BB-S100
2130
NSF/ANSI INFLUENT
CHALLENGE CONCENTRATION
2.0 mg/L
2.0 mg/L ± 10%
126,000/L
Minimum 50,000/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
.0015 mg/L ± 10%
AVERAGE INFLUENT
INTERMITTENT PEAK FEED FLOW
CONCENTRATION
2.0 mg/L Free Chloine
3.0 mg/L Free Chloramine
Buyers Name: _______________________________________
Date: ______________________________________________
Sellers Name: _______________________________________
Date ______________________________________________
The seller shall retain the signed PDS on file at the seller's place of
business for at least two years.
PERCENT REDUCTION
REQUIREMENT/MAXIMUM
PERMISSIBLE PRODUCT
WATER CONCENTRATION
≥ 50%
> 99.95%
0.005 mg/L
0.005 mg/L
0.00007 mg/L
ESTIMATED GALLON CAPACITY @
RATE GPM (LPM)
INTERMITTENT PEAK FEED FLOW
13 GPM (49.2 lpm)
264,000 Gallons (999,348 liters)
7 GPM (26.4 lpm)
132,000 Gallons (499,674 liters)
EDP# 68110146
Contact:
USA
Watts
815 Chestnut Street
North Andover, MA 01845-6098
Phone: 978-689-6066
Fax: 978-975-8350
Watts.com
Canada
Watts
5435 North Service Road
Burlington, ON L7L 5H7
Phone: 888-208-8927
Fax: 905-481-2316
Watts.ca
For Purchases Made In Iowa
AVERAGE % REDUCTION @
PEAK FLOW &
FLOW RATE GPM (LPM)
% REDUCTION
97.90% @4 GPM (15 lpm)
7 GPM (26.4 lpm) @
99.62% reduction
99.97% @4 GPM (15 lpm)
(*) >74,000 gallons
99.62% @4 GPM (15 lpm)
at 8 GPM (280,090
99.62%@4 GPM (15 lpm)
Liters @ 26.4 lpm)
98.26% @4 GPM (15 lpm)
ESTIMATED NEW CARTRIDGE
PERCENT REDUCTION OF
RATE
SUBSTANCE @ INTERMITTENT
PEAK FLOW RATE
90%
85%
© 2021 Watts
OF LEAD
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bb-s100

Table des Matières