Performance Data Sheet - Watts Pure H2O H2O-DWUF300 Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Performance Data Sheet

Pure H2O
-In U .S .-Watts Regulator Co ., N . Andover, MA 01845 (Watts .com)
-In Canada-Watts, Water Technologies (Canada), Inc . Toronto, ON M5J3G6 (Watts .ca)
3-Stage Ultra Filtration System : H2O-DWUF300
GENERAL USE CONDITIONS
WARNING
1: System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality . DO
NOT use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system . While
testing was performed under standard laboratory conditions, actual performance may vary .
2: Operating Temperature: Maximum 100
3: Operating Water Pressure: Maximum 100-psi (690 kPa)
4: Maximum flow Rate: 0 .50 gpm (1 .89 Lpm)
5: Rated Capacity: 2000 Gallons (7,550 Liters)
Note: Depending on incoming feed water conditions replacement time frame may vary .
Description
Stage 1: Sediment
Stage 2: Carbon Block
Stage 3: Ultra Filtration Membrane
This system has been tested according to NSF/ANSI Standard 42 and 53 for the reduction of the substances listed below .
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53 .
This system is certified to NSF/ANSI standard 372 for 'lead free' compliance .
Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts .
Substance
Chlorine taste and odor
Cyst
F (40 .5
C)
Minimum 40
o
o
Minimum 10 psi (69kPa)
Recommended Replacement Parts and Change Interval
Model / Part Number
H2O-F14 / 88005215
H2O-F12 / 88005217
H2O-F15 / 88005447
Percent Reduction
97%
99 .99%
Page 8
F (4 .4
C)
o
o
Influent Challenge Concentration
(mg/L unless noted)
2 .0 mg/L + 10%
minimum 50,000/mL
Change Time Frame
6 Months
6 Months/2000 gallons
12 Months
Maximum Permissible Product
Water Concentration
> = 50%
99 .95%

Publicité

Table des Matières
loading

Table des Matières