The following flowchart shows how the program I set manually:
3. BATT/PROGRAM Select
Press INC and DEC to go through all the programs and press
START/ENTER to enter LiPo BATT Program.
4. Mode Select
Press INC and DEC to go through all the modes and press START/
ENTER to enter LiPo Balance Charge Mode.
5. Battery Setting
Press START/ENTER, the present value will start to blink. Press
INC and DEC to change the value and press START/ENTER to
confirm your setting.
At the same time, the battery pack's cell count will start to blink,
press INC and DEC to change the value and press START/ENTER
to confirm your setting.
6. Program Start
Press and hold START/ENTER for 3 seconds to start the program.
The charger is detecting the battery cell
R shows the number of cells detected by the charger and S is
the number of cells set by you on the previous screen. If the two
numbers are not identical, press STOP to go back to the previous
screen to recheck the number of cells of the battery pack that
you set before going ahead.
R shows the number of cells detected by the charger and S is the
number of cells set by you on the previous screen. If the two num-
bers are identical, press START/ENTER to start the charging process.
7. Charging Status Monitor
During charge process, real-time status will be shown as seen on
the left.